Online Catalog
 
Back To Home > Baldor Generators > Industrial Gaseous Standby/Prime Power -- Industrial Gaseous Liquid Cooled (IGLC)

INDUSTRIAL GASEOUS STANDBY/PRIME POWER -- INDUSTRIAL GASEOUS LIQUID COOLED (IGLC)

The Baldor IGLC power generation systems are Industrial Gaseous Liquid Cooled generators, which operate from natural or LP gas and provide reliable standby power for industrial and commercial applications. IGLC power generation systems are available in an open configurations and weather-protective and fully sound-attenuated enclosures. Every IGLC power system is designed, engineered, built and tested to the customer's specific specifications. Solid-state engine controls and switchgear systems are designed to meet application requirements. Available in sizes from 125kW to 880kW.

Specifications

MODEL (Click Name For PDF)TLIGLC125NL-CTLIGLC145NL-CTLIGLC150NL-CTLIGLC185NL-CTLIGLC215NL-C
Gen Set RatingsClick for RatingsClick for RatingsClick for RatingsClick for RatingsClick for Ratings
Features
Large Backlit LCD with Alpha-Numeric Readout
Microprocessor-Based Design
16 Programmable Alarms/Shutdowns Set Points
4 Programmable Inputs
Alarm Horn
Not-In-Automatic Alarm
Digital Three Phase Voltage And Current Monitoring
Password-Protected Front Panel Programming
4 Programmable Outputs
Local Emergency Stop Switch
Optional NFPA 110 Level I
Digital Oil Pressure Gauge
Digital Water Temperature Gauge
Digital Battery Voltmeter
Overspeed Shutdown
Emergency Stop Shutdown
Loss Of Speed Signal
Overcrank Shutdown
Designed To Meet/Exceed UL 508, UL 2200, NFPA 70 and NFPA 110 Standards
Engine Technical Data
ManufacturerCumminsCumminsCumminsCumminsCummins
ModelGTA8.3-G1G855GTA8.3-G2GTA855-G1GTA855-G2
Type4 Cycle4 Cycle4 Cycle4 Cycle4 Cycle
Configuration6 Cylinders, In-Line6 Cylinders, In-Line6 Cylinders, In-Line6 Cylinders, In-Line6 Cylinders, In-Line
AspirationTurbocharged, After-CooledTurbocharged, After-CooledTurbocharged, After-CooledTurbocharged, After-CooledTurbocharged, After-Cooled
Displacement405.4 cu. in. (8.27 liters)855 cu. in. (14.0 liters)504.5 cu. in. (8.27 liters)855 cu. in. (14.0 liters)855 cu. in. (14.0 liters)
Bore and Stroke4.49" x 5.31"
(114 mm x 135 mm)
5.50" x 6.0"
(130 mm x 152 mm)
4.49" x 5.32"
(114 mm x 135 mm)
5.50" x 6.0"
(140 mm x 152 mm)
5.50" x 6.0"
(140 mm x 152 mm)
Compression Ratio10.5:1 (8.5:1)12.1 (10:1)10.5:1 (8.5:1)10.5:1 (8.5:1)10:1 (8.5:1)
Air Filter TypeDryDryDryDryDry
Governor TypeElectronicElectronicElectronicElectronicElectronic
Govenor ModelWoodward FlowtechWoodward FlowtechWoodward FlowtechWoodward FlowtechWoodward Flowtech
Injection Pump Type/Model75 mm75 mm75 mm75 mm75 mm
Frequency Regulation, Steady State±0.25%±0.25%±0.25%±0.25%±0.25%
Frequency Regulation, No Load to Full LoadIsochronousIsochronousIsochronousIsochronousIsochronous
Battery Voltage24V DC24V DC24V DC24V DC24V DC
Water Pump TypeCentrifugalCentrifugalCentrifugalCentrifugalCentrifugal
Coolant Capacity - Radiator Cooled91.4 qts (86.5 liters)27 qts (25.5 liters)112 qts (86.5 liters)102 qts (96 liters)102 qts (96 liters)
Coolant Capacity - Engine Only11.5 qts (10.9 liters)22 qts (21 liters)11.5 qts (10.9 liters)22.0 qts (21 liters)22.0 qts (21 liters)
Oil Pan Capacity 4-5 gals (15-18 liters)34.1-26.5 gals (9.0-7.0 liters)18.9-15.1 gals (5.0-4.0 liters)34.1-26.5 gals (9.0-7.0 liters)34.1-26.5 gals (9.0-7.0 liters)
Recommended Oil Type (SF/CC/CD -10°F to 90°F)10W-4010W-4010W-4010W-4010W-40
Engine Operational Values (50Hz)
Maximum Ambient Temperature100° F (38° C)100° F (38° C)100° F (38° C)100° F (38° C)100° F (38° C)
Heat Rejected to Coolant5575 Btu/min (98 kWm)7370 Btu/min (129 kWm)6191 Btu/min (109 kWm)8767 Btu/min (154 kWm)9936 Btu/min (175 kWm)
Heat Rejected to Aftercooler597 Btu/min (10 kWm)N/A663 Btu/min (12 kWm)1131 Btu/min (20 kWm)1282 Btu/min (23 kWm)
Maximum Power at Rated RPM165 BHP/min (123 kWm)184 BHP/min (137 kWm)187 BHP/min (140 kWm)239 BHP/min (176 kWm)274 BHP/min (204 kWm)
Coolant FlowN/A93 gpm (352 lpm)45 gpm (170 lpm)93 gpm (352 lpm)93 gpm (352 lpm)
Exhaust Temperature1375° F (746° C)1350° F (732° C)1375° F (746° C)1350° F (732° C)1350° F (732° C)
Exhaust Flow918 cfm (433 m³/min)927 cfm (438 m³/min)1019 cfm (481 m³/min)1811 cfm (855 m³/min)1949 cfm (920 m³/min)
Gas Pressure Required10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)
Minimum Pipe Size at Engine2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)
Normal Oil Pressure (High)50-70 PSI (345-483 kPa)50-70 PSI (345-483 kPa)30 PSI (207 kPa)50-70 PSI (345-483 kPa)50-70 PSI (345-483 kPa)
Engine Operational Values (60Hz)
Maximum Ambient Temperature100° F (38° C)100° F (38° C)100° F (38° C)100° F (38° C)100° F (38° C)
Heat Rejected to Coolant6736 Btu/min (38 kWm)8736 Btu/min (153 kWm)7919 Btu/min (139 kWm)10,708 Btu/min (188 kWm)12,274 Btu/min (216 kWm)
Heat Rejected to Aftercooler722 Btu/min (13 kWm)N/A848 Btu/min (15 kWm)1382 Btu/min (24 kWm)1584 Btu/min (28 kWm)
Maximum Power at Rated RPM204 BHP/min (152 kWm)220 BHP/min (164 kWm)240 BHP/min (179 kWm)293 BHP/min (219 kWm)336 BHP/min (251 kWm)
Coolant Flow55 gpm (208 lpm)113 gpm (428 lpm)55 gpm (208 lpm)113 gpm (428 lpm)113 gpm (428 lpm)
Exhaust Temperature1375° F (746° C)1350° F (732° C)1375° F (746° C)1350° F (732° C)1350° F (732° C)
Exhaust Flow1218 cfm (575 m³/min)1111 cfm (524 m³/min)1389 cfm (656 m³/min)2040 cfm (963 m³/min)2167 cfm (1023 m³/min)
Gas Pressure Required10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)
Minimum Pipe Size at Engine2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)
Normal Oil Pressure (High)50-70 PSI (345-483 kPa)50-70 PSI (345-483 kPa)30 PSI (207 kPa)50-70 PSI (345-483 kPa)50-70 PSI (345-483 kPa)
Alternator Technical Data
Generator Frame274274274274/4274/4
ExciterBrushlessBrushlessBrushlessBrushlessBrushless
Cooling FanCast Alloy AluminumCast Alloy AluminumCast Alloy AluminumCast Alloy AluminumCast Alloy Aluminum
BearingSingle, Double-ShieldedSingle, Double-ShieldedSingle, Double-ShieldedSingle, Double-ShieldedSingle, Double-Shielded
Connection TypeReconnectableReconnectableReconnectableReconnectableReconnectable
Insulation TypeClass HClass HClass HClass HClass H
Windings100% Copper100% Copper100% Copper100% Copper100% Copper
Pitch2/32/32/32/32/3
Amortisseur WindingFullFullFullFullFull
Voltage RegulatorSX460SX460SX460SX460SX460/SX440
Voltage Regulation (NL - FL)1.50%1.50%1.50%1.50%/1%1.50%/1%
Underspeed ProtectionStandardStandardStandardStandardStandard
Overexcitation ProtectionOptionalOptionalOptionalOptionalOptional
Overvoltage ProtectionOptionalOptionalOptionalOptionalOptional
Loss of Sensing ProtectionStandardStandardStandardStandardStandard
Overspeed2250 RPM2250 RPM2250 RPM2250 RPM2250 RPM
StandardsNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BS
Phase SequenceA(U), B(V), C(W)A(U), B(V), C(W)A(U), B(V), C(W)A(U), B(V), C(W)A(U), B(V), C(W)
TIF (1960 Weightings)<50<50<50<50<50
Excitation SystemShunt - PMG OptionalShunt - PMG OptionalShunt - PMG OptionalShunt - PMG OptionalShunt - PMG Optional
Alternator Performance DataClick for DataClick for DataClick for DataClick for DataClick for Data
Ventilation Requirements (50Hz)
a. Cooling Airflow Required (Unit-Mounted Radiator)16,000 cfm (7552 l/s)10,000 cfm (4720 l/s)16,000 cfm (7552 l/s)30,000 cfm (14,160 l/s)30,000 cfm (14,160 l/s)
b. Combustion Air Required338 cfm (160 l/s)315 cfm (149 l/s)375 cfm (177 l/s)674 cfm (318 l/s)725 cfm (342 l/s)
Total Ventilation Requirements (a. + b.)16,338 cfm (7712 l/s)10,315 cfm (4869 l/s)16,375 cfm (7729 l/s)30,674 cfm 14,478( l/s)30,725 cfm (14,502 l/s)
Maximum Cooling Air Restriction0.5 in. H20 (13 mm H20)0.5 in. H20 (13 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)
Recommended Minimum Intake Louver Size (Based on "Free Area")16 ft² (1.5 m²)14 ft² (1.3 m²)16 ft² (1.5 m²)35 ft² (3.3 m²)35 ft² (3.3 m²)
a. Heat Rejected To Ambient, Engine697 Btu/min (12 kWm)1798 Btu/min (32 kWm)774 Btu/min (14 kWm)990 Btu/min (17 kWm)1122 Btu/min (20 kWm)
b. Heat Rejected To Ambient, Generator701 Btu/min (12 kWm)781 Btu/min (14 kWm)794 Btu/min (14 kWm)1015 Btu/min (18 kWm)1163 Btu/min (20 kWm)
Total Heat Rejection To Ambient (a. + b.)1398 Btu/min (25 kWm)2579 Btu/min (45 kWm)1568 Btu/min (28 kWm)2005 Btu/min (35 kWm)2285 Btu/min (40 kWm)
Ventilation Requirements (60Hz)
a. Cooling Airflow Required (Unit-Mounted Radiator)16,000 cfm (7552 l/s)14,000 cfm (6608 l/s)16,000 cfm (7552 l/s)35,000 cfm (16,520 l/s)35,000 cfm (16,520 l/s)
b. Combustion Air Required450 cfm (212 l/s)379 cfm (179 l/s)516 cfm (244 l/s)757 cfm (357 l/s)803 cfm (379 l/s)
Total Ventilation Requirements (a. + b.)16,450 cfm (7764 l/s)14,379 cfm (6787 l/s)16,516 cfm (7796 l/s)35,757 cfm (16,877 l/s)35,803 cfm (16,899 l/s)
Maximum Cooling Air Restriction0.5 in. H20 (13 mm H20)0.5 in. H20 (13 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)
Recommended Minimum Intake Louver Size (Based on "Free Area")16 ft² (1.5 m²)14 ft² (1.3 m²)16 ft² (1.5 m²)35 ft² (3.3 m²)35 ft² (3.3 m²)
a. Heat Rejected To Ambient, Engine842 Btu/min (15 kWm)1798 Btu/min (32 kWm)990 Btu/min (17 kWm)1209 Btu/min (21 kWm)1386 Btu/min (24 kWm)
b. Heat Rejected To Ambient, Generator866 Btu/min (15 kWm)934 Btu/min (16 kWm)1019 Btu/min (18 kWm)1244 Btu/min (22 kWm)1427 Btu/min (25 kWm)
Total Heat Rejection To Ambient (a. + b.)1708 Btu/min (30 kWm)2732 Btu/min (48 kWm)2009 Btu/min (35 kWm)2453 Btu/min (43 kWm)2813 Btu/min (49 kWm)
Exhaust System Requirements (50Hz)
Exhaust Gas Flow918 cfm (433 m³/min)927 cfm (438 m³/min)1019 cfm (481 m³/min)1811 cfm (855 m³/min)1949 cfm (920 m³/min)
Exhaust Temperature (Dry Manifold)1375° F (746° C)1350° F (732° C)1375° F (746° C)1350° F (732° C)1350° F (732° C)
Maximum Back Pressure (Inclusive of Silencer)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)
Exhaust Outlet Size3.5 in. (88.9 mm)4 in. (101.6 mm)3.5 in. (88.9 mm)4 in. (101.6 mm)4 in. (101.6 mm)
Emissions, NOxConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Emissions, HC
Emissions, CO
Exhaust System Requirements (60Hz)
Exhaust Gas Flow1218 cfm (575 m³/min)1111 cfm (524 m³/min)1389 cfm (656 m³/min)2040 cfm (963 m³/min)2167 cfm (1023 m³/min)
Exhaust Temperature (Dry Manifold)1375° F (746° C)1350° F (732° C)1375° F (746° C)1350° F (732° C)1350° F (732° C)
Maximum Back Pressure (Inclusive of Silencer)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)
Exhaust Outlet Size3.5 in. (88.9 mm)4 in. (101.6 mm)3.5 in. (88.9 mm)4 in. (101.6 mm)4 in. (101.6 mm)
Emissions, NOx1.28 g/hp-hrConsult Tele-Lite2.87 g/hp-hrConsult Tele-LiteConsult Tele-Lite
Emissions, HC9.52 g/hp-hr16.16 g/hp-hr
Emissions, CO3.24 g/hp-hr0.62 g/hp-hr
Fuel System Requirements, Natural Gas (50Hz)
(Conversions: Cubic feet of Natural Gas/2.644 = Cubic Feet of LPG and Cubic Feet of LPG/8.533 = Gallons of LPG per hour - estimated)
Fuel Consumption, 1/4 Load538 cu.ft/hr (424 BTU/Hp-hr)959 cu.ft/hr (755 BTU/Hp-hr)932 cu.ft/hr (734 BTU/Hp-hr)1214 cu.ft/hr (955 BTU/Hp-hr)1391 cu.ft/hr (1095 BTU/Hp-hr)
Fuel Consumption, 1/2 Load987 cu.ft/hr (777 BTU/Hp-hr)1116 cu.ft/hr (878 BTU/Hp-hr)1084 cu.ft/hr (853 BTU/Hp-hr)1411 cu.ft/hr (1111 BTU/Hp-hr)1618 cu.ft/hr (1273 BTU/Hp-hr)
Fuel Consumption, 3/4 Load1286 cu.ft/hr (1012 BTU/Hp-hr)1297 cu.ft/hr (1021 BTU/Hp-hr)1261 cu.ft/hr (992 BTU/Hp-hr)1641 cu.ft/hr (1292 BTU/Hp-hr)1881 cu.ft/hr (1480 BTU/Hp-hr)
Fuel Consumption, Full Load1496 cu.ft/hr (1177 BTU/Hp-hr)1508 cu.ft/hr (1187 BTU/Hp-hr)1466 cu.ft/hr (1154 BTU/Hp-hr)1908 cu.ft/hr (1502 BTU/Hp-hr)2187 cu.ft/hr (1721 BTU/Hp-hr)
Fuel System Requirements, Natural Gas (60Hz)
(Conversions: Cubic feet of Natural Gas/2.644 = Cubic Feet of LPG and Cubic Feet of LPG/8.533 = Gallons of LPG per hour - estimated)
Fuel Consumption, 1/4 Load646 cu.ft/hr (509 BTU/Hp-hr)652 cu.ft/hr (513 BTU/Hp-hr)675 cu.ft/hr (531 BTU/Hp-hr)824 cu.ft/hr (649 BTU/Hp-hr)945 cu.ft/hr (744 BTU/Hp-hr)
Fuel Consumption, 1/2 Load1185 cu.ft/hr (932 BTU/Hp-hr)1195 cu.ft/hr (940 BTU/Hp-hr)1238 cu.ft/hr (974 BTU/Hp-hr)1511 cu.ft/hr (1189 BTU/Hp-hr)1733 cu.ft/hr (1363 BTU/Hp-hr)
Fuel Consumption, 3/4 Load1544 cu.ft/hr (1215 BTU/Hp-hr)1557 cu.ft/hr (1225 BTU/Hp-hr)1613 cu.ft/hr (1269 BTU/Hp-hr)1969 cu.ft/hr (1550 BTU/Hp-hr)2258 cu.ft/hr (1777 BTU/Hp-hr)
Fuel Consumption, Full Load1795 cu.ft/hr (1413 BTU/Hp-hr)1810 cu.ft/hr (1424 BTU/Hp-hr)1875 cu.ft/hr (1476 BTU/Hp-hr)2290 cu.ft/hr (1802 BTU/Hp-hr)2625 cu.ft/hr (2066 BTU/Hp-hr)
Heat Exchanger Cooling System Requirements (50Hz)
Minimum Raw Water Flow (City Water)Consult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Maximum Supply Water Temperature (F°)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)
Heat Exchanger Cooling System Requirements (60Hz)
Minimum Raw Water Flow (City Water)Consult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Maximum Supply Water Temperature (F°)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)
Remote Cooling System Requirements (50Hz)
Maximum Coolant Static Head60 ft (18 m)46 ft (14 m)60 ft (18 m)46 ft (14 m)46 ft (14 m)
Ventilation Required (Based on 25F° Temperature Rise)3106 cfm (55 lps)5732 cfm (101 lps)3485 cfm (61 lps)4455 cfm (78 lps)5079 cfm (89 lps)
Remote Cooling System Requirements (60Hz)
Maximum Coolant Static Head60 ft (18 m)46 ft (14 m)60 ft (18 m)46 ft (14 m)46 ft (14 m)
Ventilation Required (Based on 25F° Temperature Rise)3796 cfm (67 lps)6071 cfm (107 lps)4465 cfm (78 lps)5451 cfm (96 lps)6251 cfm (110 lps)
Dimensions (Open Unit Configuration -- Accessories Not Included)
Length109 in (2769 mm)121 in (3073 mm)106 in (2692 mm)149 in (3785 mm)150 in (3810 mm)
Width40 in (1016 mm)35 in (889 mm)40 in (1016 mm)60 in (1524 mm)60 in (1524 mm)
Height55 in (1397 mm)71 in (1803 mm)55 in (1397 mm)76 in (1931 mm)76 in (1931 mm)
Weight3840 lbs (1742 Kg)5240 lbs (2377 Kg)4100 lbs (1860 Kg)7202 lbs (3267 Kg)7506 lbs (3405 Kg)
Cubes (Approximate)139 ft173 ft135 ft393 ft393 ft
Control Panel Options and Accessories
High Coolant Temperature Pre-Alarm
Low Oil Pressure Pre-Alarm
Alarm Horn with Switch
Remote Start-Stop
Remote Annunciator
Run Relay (Per NFPA 110)
Dry Contacts (Per NFPA 110)
Engine Exhaust System Options and Accessories
Industrial Silencer
Residential Silencer
Critical Silencer
Exhaust Flex
Rain Cap
Generator Options and Accessories
Main Line Circuit Breaker
Shunt Trip
Alternator Heater
Field Circuit Breaker
PMG
Engine Electrical System Options and Accessories
Batteries
Battery Rack
Battery Cables
Battery Charger (Automatic)
Battery Charger (Trickle)
Engine Fuel System Options and Accessories
Flexible Fuel Lines
Miscellaneous Options and Accessories
Weather-Protective Enclosure
Sound-Attentuated Enclosure
Vibration Isolators
Coolant Heater
NOTES:
Standby Ratings: Standby ratings are applicable for supplying emergency power for the duration of a utility power outage. Primary power to the installation is utility supplied. No overload capability for standby rating. Standby ratings in accordance with ISO 3046, BS 55114, DIN 6271.
Continuous Power Rating: Continuous power is the maximum power available for continuous duty. A 10% overload capacity is available for 1 hour out of 12 hours of operation. Prime Power ratings in accordance with ISO 3046, BS55114, DIN 6271.
For additional information, please consult Tele-Lite.
Manufacturer reserves the right to implement specifications or design changes without notice.

MODEL (Click Name For PDF)TLIGLC250NL-CTLIGLC280NL-CTLIGLC325NL-CTLIGLC350NL-CTLIGLC400NL-C
Gen Set RatingsClick for RatingsClick for RatingsClick for RatingsClick for RatingsClick for Ratings
Features
Large Backlit LCD with Alpha-Numeric Readout
Microprocessor-Based Design
16 Programmable Alarms/Shutdowns Set Points
4 Programmable Inputs
Alarm Horn
Not-In-Automatic Alarm
Digital Three Phase Voltage And Current Monitoring
Password-Protected Front Panel Programming
4 Programmable Outputs
Local Emergency Stop Switch
Optional NFPA 110 Level I
Digital Oil Pressure Gauge
Digital Water Temperature Gauge
Digital Battery Voltmeter
Overspeed Shutdown
Emergency Stop Shutdown
Loss Of Speed Signal
Overcrank Shutdown
Designed To Meet/Exceed UL 508, UL 2200, NFPA 70 and NFPA 110 Standards
Engine Technical Data
ManufacturerCumminsCumminsCumminsCumminsCummins
ModelGTA855-G3GTA14-G2GTA19-GEGTA19-2GEGTA28
Type4 Cycle4 Cycle4 Cycle4 Cycle4 Cycle
Configuration6 Cylinders, In-Line6 Cylinders, In-Line6 Cylinders, In-Line6 Cylinders, In-Line12 Cylinders, V-12
AspirationTurbocharged, After-CooledTurbocharged, After-CooledTurbocharged, After-CooledTurbocharged, After-CooledTurbocharged, After-Cooled
Displacement855 cu. in. (14.0 liters)855 cu. in. (14.0 liters)1150 cu. in. (19.0 liters)1150 cu. in. (19.0 liters)1710 cu. in. (28.0 liters)
Bore and Stroke5.50" x 6.0"
(140 mm x 152 mm)
5.50" x 6.0"
(130 mm x 152 mm)
6.25" x 6.25"
(159 mm x 159 mm)
6.25" x 6.25"
(159 mm x 159 mm)
5.50" x 6.0"
(140 mm x 152 mm)
Compression Ratio10.5:1 (8.5:1)11:110.5:1 (8.5:1)10:1 (8.5:1)8.5:1
Air Filter TypeDryDryDryDryDry
Governor TypeElectronicElectronicElectronicElectronicElectronic
Govenor ModelWoodward FlowtechWoodward FlowtechBarber-ColmanBarber-ColmanBarber-Colman
Injection Pump Type/Model75 mm75 mm8400 Plus 48400 Plus 48400 Plus 4
Frequency Regulation, Steady State±0.25%±0.25%±0.25%±0.25%±0.25%
Frequency Regulation, No Load to Full LoadIsochronousIsochronousIsochronousIsochronousIsochronous
Battery Voltage24V DC24V DC24V DC24V DC24V DC
Water Pump TypeCentrifugalCentrifugalCentrifugalCentrifugalCentrifugal
Coolant Capacity - Radiator Cooled102 qts (96 liters)122 qts (115 liters)133 qts (126 liters)133 qts (126 liters)174 qts (165 liters)
Coolant Capacity - Engine Only22 qts (21 liters)20 qts (19 liters)32 qts (30 liters)32 qts (30 liters)85 qts (80 liters)
Oil Pan Capacity 34.1-26.5 gals (9.0-7.0 liters)36.0-30.3 gals (9.5-8.0 liters)37.9-32.2 gals (10.0-8.5 liters)37.9-32.2 gals (10.0-8.5 liters)68-61 gals (18-16 liters)
Recommended Oil Type (SF/CC/CD -10°F to 90°F)10W-4010W-4010W-4010W-4010W-40
Engine Operational Values (50Hz)
Maximum Ambient Temperature100° F (38° C)100° F (38° C)100° F (38° C)N/A100° F (38° C)
Heat Rejected to Coolant12,040 Btu/min (212 kWm)14,098 Btu/min (248 kWm)15,440 Btu/min (271 kWm)N/A23,753 Btu/min (417 kWm)
Heat Rejected to Aftercooler1554 Btu/min (27 kWm)1819 Btu/min (32 kWm)1992 Btu/min (35 kWm)N/A3065 Btu/min (54 kWm)
Maximum Power at Rated RPM328 BHP/min (245 kWm)366 BHP/min (273 kWm)416 BHP/min (310 kWm)N/A617 BHP/min (460 kWm)
Coolant Flow93 gpm (352 lpm)89 gpm (337 lpm)155 gpm (587 lpm)N/A176 gpm (666 lpm)
Exhaust Temperature1350° F (732° C)1300° F (704° C)1350° F (732° C)N/A1350° F (732° C)
Exhaust Flow2159 cfm (1019 m³/min)2043 cfm (964 m³/min)2697 cfm (1273 m³/min)N/A3917 cfm (1849 m³/min)
Gas Pressure Required10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)N/A10-20 in. H2O (254-508 mm H2O)
Minimum Pipe Size at Engine2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)N/A2 in. (51 mm)
Normal Oil Pressure (High)50-70 PSI (345-483 kPa)35-45 PSI (241-310 kPa)50-70 PSI (345-483 kPa)N/A50-90 PSI (345-621 kPa)
Engine Operational Values (60Hz)
Maximum Ambient Temperature100° F (38° C)100° F (38° C)100° F (38° C)100° F (38° C)100° F (38° C)
Heat Rejected to Coolant14,074 Btu/min (247 kWm)16,169 Btu/min (284 kWm)20,059 Btu/min (352 kWm)18,657 Btu/min (328 kWm)27,354 Btu/min (481 kWm)
Heat Rejected to Aftercooler1816 Btu/min (32 kWm)2086 Btu/min (37 kWm)2599 Btu/min (46 kWm)2407 Btu/min (42 kWm)3530 Btu/min (62 kWm)
Maximum Power at Rated RPM383 BHP/min (286 kWm)435 BHP/min (325 kWm)495 BHP/min (369 kWm)531 BHP/min (396 kWm)730 BHP/min (545 kWm)
Coolant Flow113 gpm (428 lpm)113 gpm (428 lpm)189 gpm (717 lpm)189 gpm (717 lpm)214 gpm (810 lpm)
Exhaust Temperature1350° F (732° C)1300° F (704° C)1350° F (732° C)1350° F (732° C)1350° F (732° C)
Exhaust Flow2328 cfm (1099 m³/min)2372 cfm (1120 m³/min)3489 cfm (1647 m³/min)3215 cfm (1517 m³/min)4778 cfm (2255 m³/min)
Gas Pressure Required10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)
Minimum Pipe Size at Engine2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)
Normal Oil Pressure (High)50-70 PSI (345-483 kPa)35-45 PSI (241-310 kPa)50-70 PSI (345-483 kPa)50-70 PSI (345-483 kPa)50-90 PSI (345-621 kPa)
Alternator Technical Data
Generator Frame4444/55
ExciterBrushlessBrushlessBrushlessBrushlessBrushless
Cooling FanCast Alloy AluminumCast Alloy AluminumCast Alloy AluminumCast Alloy AluminumCast Alloy Aluminum
BearingSingle, Double-ShieldedSingle, Double-ShieldedSingle, Double-ShieldedSingle, Double-ShieldedSingle, Double-Shielded
Connection TypeReconnectableReconnectableReconnectableReconnectableReconnectable
Insulation TypeClass HClass HClass HClass HClass H
Windings100% Copper100% Copper100% Copper100% Copper100% Copper
Pitch2/32/32/32/32/3
Amortisseur WindingFullFullFullFullFull
Voltage RegulatorSX440SX440SX440SX440SX440
Voltage Regulation (NL - FL)1.00%1.00%1.00%1.00%1.00%
Underspeed ProtectionStandardStandardStandardStandardStandard
Overexcitation ProtectionOptionalOptionalOptionalOptionalOptional
Overvoltage ProtectionOptionalOptionalOptionalOptionalOptional
Loss of Sensing ProtectionStandardStandardStandardStandardStandard
Overspeed2250 RPM2250 RPM2250 RPM2250 RPM2250 RPM
StandardsNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BS
Phase SequenceA(U), B(V), C(W)A(U), B(V), C(W)A(U), B(V), C(W)A(U), B(V), C(W)A(U), B(V), C(W)
TIF (1960 Weightings)<50<50<50<50<50
Excitation SystemShunt - PMG OptionalShunt - PMG OptionalShunt - PMG OptionalShunt - PMG OptionalShunt - PMG Optional
Alternator Performance DataClick for DataClick for DataClick for DataClick for DataClick for Data
Ventilation Requirements (50Hz)
a. Cooling Airflow Required (Unit-Mounted Radiator)30,000 cfm (14,160 l/s)37,000 cfm (17,464 l/s)40,000 cfm (18,800 l/s)NA61,000 cfm (28,789 l/s)
b. Combustion Air Required800 cfm (378 l/s)699 cfm (330 l/s)930 cfm (439 l/s)NA1348 cfm (636 l/s)
Total Ventilation Requirements (a. + b.)30,800 cfm (14,538 l/s)37,699 cfm (17,794 l/s)40,930 cfm (19,239 l/s)NA62,348 cfm (29,425 l/s)
Maximum Cooling Air Restriction0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)NA0.5 in. H20 (12.8 mm H20)
Recommended Minimum Intake Louver Size (Based on "Free Area")35 ft² (3.3 m²)37 ft² (3.4 m²)40 ft² (3.7 m²)NA74 ft² (6.9 m²)
a. Heat Rejected To Ambient, Engine1359 Btu/min (24 kWm)1592 Btu/min (28 kWm)1743 Btu/min (31 kWm)NA2682 Btu/min (47 kWm)
b. Heat Rejected To Ambient, Generator1393 Btu/min (24 kWm)1554 Btu/min (27 kWm)1766 Btu/min (31 kWm)NA2620 Btu/min (46 kWm)
Total Heat Rejection To Ambient (a. + b.)2752 Btu/min (48 kWm)3146 Btu/min (55 kWm)3509 Btu/min (62 kWm)NA5302 Btu/min (93 kWm)
Ventilation Requirements (60Hz)
a. Cooling Airflow Required (Unit-Mounted Radiator)35,000 cfm (16,520 l/s)37,000 cfm (17,464 l/s)40,000 cfm (18,880 l/s)40,000 cfm (18,880 l/s)74,000 cfm (34,924 l/s)
b. Combustion Air Required860 cfm (406 l/s)872 cfm (412 l/s)1292 cfm (610 l/s)1190 cfm (562 l/s)1769 cfm (835 l/s)
Total Ventilation Requirements (a. + b.)35,860 cfm (16,926 l/s)37,872 cfm (17,876 l/s)41,292 cfm (19,490 l/s)41,190 cfm (19,442 l/s)75,769 cfm (35,759 l/s)
Maximum Cooling Air Restriction0.5 in. H20 (13 mm H20)0.5 in. H20 (13 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)
Recommended Minimum Intake Louver Size (Based on "Free Area")35 ft² (3.3 m²)37 ft² (3.4 m²)40 ft² (3.7 m²)40 ft² (3.7 m²)74 ft² (6.9 m²)
a. Heat Rejected To Ambient, Engine1589 Btu/min (28 kWm)1826 Btu/min (32 kWm)2265 Btu/min (40 kWm)2160 Btu/min (38 kWm)3088 Btu/min (54 kWm)
b. Heat Rejected To Ambient, Generator1626 Btu/min (29 kWm)1847 Btu/min (32 kWm)2100 Btu/min (37 kWm)2255 Btu/min (40 kWm)3100 Btu/min (54 kWm)
Total Heat Rejection To Ambient (a. + b.)3215 Btu/min (56 kWm)3673 Btu/min (65 kWm)4365 Btu/min (77 kWm)4415 Btu/min (78 kWm)6188 Btu/min (109 kWm)
Exhaust System Requirements (50Hz)
Exhaust Gas Flow2159 cfm (1019 m³/min)2043 cfm (964 m³/min)2697 cfm (1273 m³/min)N/A3917 cfm (1849 m³/min)
Exhaust Temperature (Dry Manifold)1350° F (732° C)1300° F (704° C)1350° F (732° C)N/A1350° F (732° C)
Maximum Back Pressure (Inclusive of Silencer)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)N/A2 in. hg (50.8 mm hg)
Exhaust Outlet Size4 in. (101.6 mm)4 in. (101.6 mm)5 in. (127 mm)N/A4 in. (101.6 mm)
Emissions, NOxConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Emissions, HC
Emissions, CO
Exhaust System Requirements (60Hz)
Exhaust Gas Flow2328 cfm (1099 m³/min)2372 cfm (1120 m³/min)3489 cfm (1647 m³/min)3215 cfm (1517 m³/min)4778 cfm (2255 m³/min)
Exhaust Temperature (Dry Manifold)1350° F (732° C)1300° F (704° C)1350° F (732° C)1350° F (732° C)1350° F (732° C)
Maximum Back Pressure (Inclusive of Silencer)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)
Exhaust Outlet Size4 in. (101.6 mm)4 in. (101.6 mm)5 in. (127 mm)5 in. (127 mm)4 in. (101.6 mm)
Emissions, NOxConsult Tele-Lite2.58 g/hp-hr2.35 g/hp-hr2.35 g/hp-hrConsult Tele-Lite
Emissions, HC13.47 g/hp-hr15.78 g/hp-hr15.78 g/hp-hr
Emissions, CO4.07 g/hp-hr0.37 g/hp-hr0.37 g/hp-hr
Fuel System Requirements, Natural Gas (50Hz)
(Conversions: Cubic feet of Natural Gas/2.644 = Cubic Feet of LPG and Cubic Feet of LPG/8.533 = Gallons of LPG per hour - estimated)
Fuel Consumption, 1/4 Load1595 cu.ft/hr (1256 BTU/Hp-hr)1747 cu.ft/hr (1375 BTU/Hp-hr)2076 cu.ft/hr (1634 BTU/Hp-hr)N/A3044 cu.ft/hr (2395 BTU/Hp-hr)
Fuel Consumption, 1/2 Load1855 cu.ft/hr (1460 BTU/Hp-hr)2032 cu.ft/hr (1599 BTU/Hp-hr)2414 cu.ft/hr (1900 BTU/Hp-hr)N/A3539 cu.ft/hr (2785 BTU/Hp-hr)
Fuel Consumption, 3/4 Load2157 cu.ft/hr (1698 BTU/Hp-hr)2362 cu.ft/hr (1859 BTU/Hp-hr)2807 cu.ft/hr (2209 BTU/Hp-hr)N/A4115 cu.ft/hr (3239 BTU/Hp-hr)
Fuel Consumption, Full Load2508 cu.ft/hr (1974 BTU/Hp-hr)2747 cu.ft/hr (2162 BTU/Hp-hr)3264 cu.ft/hr (2569 BTU/Hp-hr)N/A4785 cu.ft/hr (3766 BTU/Hp-hr)
Fuel System Requirements, Natural Gas (60Hz)
(Conversions: Cubic feet of Natural Gas/2.644 = Cubic Feet of LPG and Cubic Feet of LPG/8.533 = Gallons of LPG per hour - estimated)
Fuel Consumption, 1/4 Load1084 cu.ft/hr (853 BTU/Hp-hr)1209 cu.ft/hr (951 BTU/Hp-hr)1463 cu.ft/hr (1130 BTU/Hp-hr)1544 cu.ft/hr (1215 BTU/Hp-hr)2106 cu.ft/hr (1657 BTU/Hp-hr)
Fuel Consumption, 1/2 Load1987 cu.ft/hr (1563 BTU/Hp-hr)2216 cu.ft/hr (1744 BTU/Hp-hr)2633 cu.ft/hr (2072 BTU/Hp-hr)2831 cu.ft/hr (2228 BTU/Hp-hr)3861 cu.ft/hr (3039 BTU/Hp-hr)
Fuel Consumption, 3/4 Load2589 cu.ft/hr (2037 BTU/Hp-hr)2888 cu.ft/hr (2273 BTU/Hp-hr)3431 cu.ft/hr (2701 BTU/Hp-hr)3689 cu.ft/hr (2904 BTU/Hp-hr)5031 cu.ft/hr (3959 BTU/Hp-hr)
Fuel Consumption, Full Load3010 cu.ft/hr (2369 BTU/Hp-hr)3358 cu.ft/hr (2643 BTU/Hp-hr)3990 cu.ft/hr (3140 BTU/Hp-hr)4290 cu.ft/hr (3376 BTU/Hp-hr)5850 cu.ft/hr (4604 BTU/Hp-hr)
Heat Exchanger Cooling System Requirements (50Hz)
Minimum Raw Water Flow (City Water)Consult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Maximum Supply Water Temperature (F°)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)
Heat Exchanger Cooling System Requirements (60Hz)
Minimum Raw Water Flow (City Water)Consult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Maximum Supply Water Temperature (F°)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)
Remote Cooling System Requirements (50Hz)
Maximum Coolant Static Head46 ft (14 m)46 ft (14 m)60 ft (18 m)N/A60 ft (18 m)
Ventilation Required (Based on 25F° Temperature Rise)6115 cfm (107 lps)6991 cfm (123 lps)7799 cfm (137 lps)N/A11,782 cfm (207 lps)
Remote Cooling System Requirements (60Hz)
Maximum Coolant Static Head46 ft (14 m)46 ft (14 m)60 ft (18 m)60 ft (18 m)60 ft (18 m)
Ventilation Required (Based on 25F° Temperature Rise)7145 cfm (126 lps)8162 cfm (143 lps)9701 cfm (170 lps)9811 cfm (172 lps)13,751 cfm (242 lps)
Dimensions (Open Unit Configuration -- Accessories Not Included)
Length145 in (3683 mm)148 in (3759 mm)136 in (3453 mm)136 in (3453 mm)168 in (4267 mm)
Width60 in (1524 mm)61 in (1549 mm)58 in (1473 mm)58 in (1473 mm)95 in (2413 mm)
Height76 in (1931 mm)74 in (1880 mm)80 in (2032 mm)80 in (2032 mm)96 in (2438 mm)
Weight8539 lbs (3873 Kg)9569 lbs (4340 Kg)10,290 lbs (4667 Kg)10,290 lbs (4667 Kg)16,000 lbs (7257 Kg)
Cubes (Approximate)382 ft386 ft365 ft365 ft886 ft
Control Panel Options and Accessories
High Coolant Temperature Pre-Alarm
Low Oil Pressure Pre-Alarm
Alarm Horn with Switch
Remote Start-Stop
Remote Annunciator
Run Relay (Per NFPA 110)
Dry Contacts (Per NFPA 110)
Engine Exhaust System Options and Accessories
Industrial Silencer
Residential Silencer
Critical Silencer
Exhaust Flex
Rain Cap
Generator Options and Accessories
Main Line Circuit Breaker
Shunt Trip
Alternator Heater
Field Circuit Breaker
PMG
Engine Electrical System Options and Accessories
Batteries
Battery Rack
Battery Cables
Battery Charger (Automatic)
Battery Charger (Trickle)
Engine Fuel System Options and Accessories
Flexible Fuel Lines
Miscellaneous Options and Accessories
Weather-Protective Enclosure
Sound-Attentuated Enclosure
Vibration Isolators
Coolant Heater
NOTES:
Standby Ratings: Standby ratings are applicable for supplying emergency power for the duration of a utility power outage. Primary power to the installation is utility supplied. No overload capability for standby rating. Standby ratings in accordance with ISO 3046, BS 55114, DIN 6271.
Continuous Power Rating: Continuous power is the maximum power available for continuous duty. A 10% overload capacity is available for 1 hour out of 12 hours of operation. Prime Power ratings in accordance with ISO 3046, BS55114, DIN 6271.
For additional information, please consult Tele-Lite.
Manufacturer reserves the right to implement specifications or design changes without notice.

MODEL (Click Name For PDF)TLIGLC485NL-CTLIGLC500N-CTLIGLC575NL-CTLIGLC625NL-CTLIGLC675NL-C
Gen Set RatingsClick for RatingsClick for RatingsClick for RatingsClick for RatingsClick for Ratings
Features
Large Backlit LCD with Alpha-Numeric Readout
Microprocessor-Based Design
16 Programmable Alarms/Shutdowns Set Points
4 Programmable Inputs
Alarm Horn
Not-In-Automatic Alarm
Digital Three Phase Voltage And Current Monitoring
Password-Protected Front Panel Programming
4 Programmable Outputs
Local Emergency Stop Switch
Optional NFPA 110 Level I
Digital Oil Pressure Gauge
Digital Water Temperature Gauge
Digital Battery Voltmeter
Overspeed Shutdown
Emergency Stop Shutdown
Loss Of Speed Signal
Overcrank Shutdown
Designed To Meet/Exceed UL 508, UL 2200, NFPA 70 and NFPA 110 Standards
Engine Technical Data
ManufacturerCumminsCumminsCumminsCumminsCummins
ModelGTA28GTA28GTA38-G1GTA38-G2GTA38-G3
Type4 Cycle4 Cycle4 Cycle4 Cycle4 Cycle
Configuration12 Cylinders, V-1212 Cylinders, V-1212 Cylinders, 60°-V12 Cylinders, 60°-V12 Cylinders, 60°-V
AspirationTurbocharged, After-CooledTurbocharged, After-CooledTurbocharged, After-CooledTurbocharged, After-CooledTurbocharged, After-Cooled
Displacement1710 cu. in. (28.0 liters)1710 cu. in. (28.0 liters)2300 cu. in. (37.8 liters)2300 cu. in. (37.8 liters)2300 cu. in. (37.8 liters)
Bore and Stroke5.50" x 6.0"
(140 mm x 152 mm)
5.50" x 6.0"
(130 mm x 152 mm)
6.25" x 6.25"
(159 mm x 159 mm)
6.25" x 6.25"
(159 mm x 159 mm)
6.25" x 6.25"
(159 mm x 159 mm)
Compression Ratio8.5:110:18.5:18.5:18.5:1
Air Filter TypeDryDryDryDryDry
Governor TypeElectronicElectronicElectronicElectronicElectronic
Govenor ModelBarber-ColmanBarber-ColmanWoodward FlowtechWoodward FlowtechWoodward Flowtech
Injection Pump Type/Model75 mm75 mm8400 Plus 48400 Plus 48400 Plus 4
Frequency Regulation, Steady State±0.25%±0.25%±0.25%±0.25%±0.25%
Frequency Regulation, No Load to Full LoadIsochronousIsochronousIsochronousIsochronousIsochronous
Battery Voltage24V DC24V DC24V DC24V DC24V DC
Water Pump TypeCentrifugalCentrifugalCentrifugalCentrifugalCentrifugal
Coolant Capacity - Radiator Cooled174 qts (165 liters)174 qts (165 liters)TBATBATBA
Coolant Capacity - Engine Only85 qts (80 liters)85 qts (80 liters)142 qts (134 liters)142 qts (134 liters)142 qts (134 liters)
Oil Pan Capacity 68-61 gals (18-16 liters)68-61 gals (18-16 liters)140-114 gals (37-30 liters)140-114 gals (37-30 liters)140-114 gals (37-30 liters)
Recommended Oil Type (SF/CC/CD -10°F to 90°F)10W-4010W-4010W-4010W-4010W-40
Engine Operational Values (50Hz)
Maximum Ambient Temperature100° F (38° C)100° F (38° C)100° F (38° C)100° F (38° C)100° F (38° C)
Heat Rejected to Coolant23,753 Btu/min (417 kWm)25,567 Btu/min (449 kWm)30,580 Btu/min (537 kWm)32,824 Btu/min (577 kWm)35,256 Btu/min (417 kWm)
Heat Rejected to Aftercooler3065 Btu/min (54 kWm)3299 Btu/min (58 kWm)2946 Btu/min (52 kWm)4235 Btu/min (74 kWm)4549 Btu/min (80 kWm)
Maximum Power at Rated RPM617 BHP/min (460 kWm)644 BHP/min (480 kWm)744 BHP/min (555 kWm)804 BHP/min (600 kWm)871 BHP/min (650 kWm)
Coolant Flow176 gpm (666 lpm)176 gpm (666 lpm)345 gpm (1306 lpm)345 gpm (1306 lpm)345 gpm (1306 lpm)
Exhaust Temperature1350° F (732° C)1350° F (732° C)1350° F (732° C)1350° F (732° C)1350° F (732° C)
Exhaust Flow3917 cfm (1849 m³/min)4070 cfm (1921 m³/min)5378 cfm (2538 m³/min)5573 cfm (2630 m³/min)5769 cfm (2723 m³/min)
Gas Pressure Required10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)
Minimum Pipe Size at Engine2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)
Normal Oil Pressure (High)50-90 PSI (345-621 kPa)50-90 PSI (345-621 kPa)45-70 PSI (310-483 kPa)45-70 PSI (310-483 kPa)45-70 PSI (310-483 kPa)
Engine Operational Values (60Hz)
Maximum Ambient Temperature100° F (38° C)100° F (38° C)100° F (38° C)100° F (38° C)100° F (38° C)
Heat Rejected to Coolant27,354 Btu/min (481 kWm)28,406 Btu/min (499 kWm)36,378 Btu/min (639 kWm)38,660 Btu/min (679 kWm)41,381 Btu/min (727 kWm)
Heat Rejected to Aftercooler3530 Btu/min (62 kWm)3365 Btu/min (64 kWm)4694 Btu/min (82 kWm)4988 Btu/min (88 kWm)5340 Btu/min (94 kWm)
Maximum Power at Rated RPM730 BHP/min (545 kWm)770 BHP/min (574 kWm)892 BHP/min (665 kWm)965 BHP/min (720 kWm)1045 BHP/min (780 kWm)
Coolant Flow214 gpm (810 lpm)214 gpm (810 lpm)411 gpm (1556 lpm)411 gpm (1556 lpm)411 gpm (1556 lpm)
Exhaust Temperature1350° F (732° C)1350° F (732° C)1350° F (732° C)1350° F (732° C)1350° F (732° C)
Exhaust Flow4778 cfm (2255 m³/min)4863 cfm (2295 m³/min)5680 cfm (2681 m³/min)6119 cfm (2888 m³/min)6560 cfm (3096 m³/min)
Gas Pressure Required10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)
Minimum Pipe Size at Engine2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)
Normal Oil Pressure (High)50-90 PSI (345-621 kPa)50-90 PSI (345-621 kPa)45-70 PSI (310-483 kPa)45-70 PSI (310-483 kPa)45-70 PSI (310-483 kPa)
Alternator Technical Data
Generator Frame555/65/66
ExciterBrushlessBrushlessBrushlessBrushlessBrushless
Cooling FanCast Alloy AluminumCast Alloy AluminumCast Alloy AluminumCast Alloy AluminumCast Alloy Aluminum
BearingSingle, Double-ShieldedSingle, Double-ShieldedSingle, Double-ShieldedSingle, Double-ShieldedSingle, Double-Shielded
Connection TypeReconnectableReconnectableReconnectableReconnectableReconnectable
Insulation TypeClass HClass HClass HClass HClass H
Windings100% Copper100% Copper100% Copper100% Copper100% Copper
Pitch2/32/32/32/32/3
Amortisseur WindingFullFullFullFullFull
Voltage RegulatorSX440SX440SX440/MX321SX440/MX321MX321
Voltage Regulation (NL - FL)1.00%1.00%1.00%/0.50%1.00%/0.50%0.50%
Underspeed ProtectionStandardStandardStandardStandardStandard
Overexcitation ProtectionOptionalOptionalOptional/StandardOptional/StandardStandard
Overvoltage ProtectionOptionalOptionalOptional/StandardOptional/StandardStandard
Loss of Sensing ProtectionStandardStandardStandardStandardStandard
Overspeed2250 RPM2250 RPM2250 RPM2250 RPM2250 RPM
StandardsNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BS
Phase SequenceA(U), B(V), C(W)A(U), B(V), C(W)A(U), B(V), C(W)A(U), B(V), C(W)A(U), B(V), C(W)
TIF (1960 Weightings)<50<50<50<50<50
Excitation SystemShunt - PMG OptionalShunt - PMG OptionalOptional on 5 Frame, Standard on 6 FrameOptional on 5 Frame, Standard on 6 FramePMG Standard
Alternator Performance DataClick for DataClick for DataClick for DataClick for DataClick for Data
Ventilation Requirements (50Hz)
a. Cooling Airflow Required (Unit-Mounted Radiator)61,000 cfm (28,789 l/s)61,000 cfm (28,789 l/s)75,000 cfm (35,400 l/s)75,000 cfm (35,400 l/s)75,000 cfm (35,400 l/s)
b. Combustion Air Required1348 cfm (636 l/s)1399 cfm (660 l/s)1949 cfm (920 l/s)2017 cfm (952 l/s)2085 cfm (984 l/s)
Total Ventilation Requirements (a. + b.)62,348 cfm (29,425 l/s)62,399 cfm (29,449 l/s)76,949 cfm (36,320 l/s)77,017 cfm (36,352 l/s)77,085 cfm (36,384 l/s)
Maximum Cooling Air Restriction0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)
Recommended Minimum Intake Louver Size (Based on "Free Area")74 ft² (6.9 m²)74 ft² (6.9 m²)75 ft² (7.0 m²)75 ft² (7.0 m²)75 ft² (7.0 m²)
a. Heat Rejected To Ambient, Engine2682 Btu/min (47 kWm)2887 Btu/min (51 kWm)3453 Btu/min (61 kWm)3706 Btu/min (65 kWm)3980 Btu/min (70 kWm)
b. Heat Rejected To Ambient, Generator2620 Btu/min (46 kWm)2887 Btu/min (48 kWm)3159 Btu/min (56 kWm)3414 Btu/min (60 kWm)3698 Btu/min (65 kWm)
Total Heat Rejection To Ambient (a. + b.)5302 Btu/min (93 kWm)5622 Btu/min (99 kWm)6612 Btu/min (116 kWm)7120 Btu/min (125 kWm)7678 Btu/min (135 kWm)
Ventilation Requirements (60Hz)
a. Cooling Airflow Required (Unit-Mounted Radiator)74,000 cfm (34,924 l/s)74,000 cfm (34,924 l/s)75,000 cfm (35,400 l/s)75,000 cfm (35,400 l/s)75,000 cfm (35,400 l/s)
b. Combustion Air Required1769 cfm (835 l/s)1799 cfm (850 l/s)2094 cfm (988 l/s)2257 cfm (1065 l/s)2420 cfm (1142 l/s)
Total Ventilation Requirements (a. + b.)75,769 cfm (35,759 l/s)75,799 cfm (35,774 l/s)77,094 cfm (36,388 l/s)77,257 cfm (36,465 l/s)77,420 cfm (35,759 l/s)
Maximum Cooling Air Restriction0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)
Recommended Minimum Intake Louver Size (Based on "Free Area")74 ft² (6.9 m²)74 ft² (6.9 m²)75 ft² (7.0 m²)75 ft² (7.0 m²)75 ft² (7.0 m²)
a. Heat Rejected To Ambient, Engine3088 Btu/min (54 kWm)3207 Btu/min (56 kWm)4107 Btu/min (72 kWm)4365 Btu/min (77 kWm)4672 Btu/min (54 kWm)
b. Heat Rejected To Ambient, Generator3100 Btu/min (54 kWm)3270 Btu/min (57 kWm)3788 Btu/min (67 kWm)4098 Btu/min (72 kWm)4437 Btu/min (54 kWm)
Total Heat Rejection To Ambient (a. + b.)6188 Btu/min (109 kWm)6477 Btu/min (114 kWm)7895 Btu/min (139 kWm)8463 Btu/min (149 kWm)9109 Btu/min (109 kWm)
Exhaust System Requirements (50Hz)
Exhaust Gas Flow3917 cfm (1849 m³/min)4070 cfm (1921 m³/min)5378 cfm (2538 m³/min)5573 cfm (2630 m³/min)5769 cfm (2723 m³/min)
Exhaust Temperature (Dry Manifold)1350° F (732° C)1350° F (732° C)1350° F (732° C)1350° F (732° C)1350° F (732° C)
Maximum Back Pressure (Inclusive of Silencer)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)
Exhaust Outlet Size4 in. (101.6 mm)4 in. (101.6 mm)5 in. (127 mm)5 in. (127 mm)5 in. (127 mm)
Emissions, NOxConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Emissions, HC
Emissions, CO
Exhaust System Requirements (60Hz)
Exhaust Gas Flow4778 cfm (2255 m³/min)4863 cfm (2295 m³/min)5680 cfm (2681 m³/min)6119 cfm (2888 m³/min)6560 cfm (3096 m³/min)
Exhaust Temperature (Dry Manifold)1350° F (732° C)1350° F (732° C)1350° F (732° C)1350° F (732° C)1350° F (732° C)
Maximum Back Pressure (Inclusive of Silencer)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)
Exhaust Outlet Size4 in. (101.6 mm)4 in. (101.6 mm)5 in. (127 mm)5 in. (127 mm)5 in. (127 mm)
Emissions, NOxConsult Tele-Lite4.5 g/hp-hr2.71 g/hp-hr2.77 g/hp-hr2.82 g/hp-hr
Emissions, HC16.5 g/hp-hr17.89 g/hp-hr17.53 g/hp-hr17.34 g/hp-hr
Emissions, CO1.52 g/hp-hr4.87 g/hp-hr4.77 g/hp-hr4.70 g/hp-hr
Fuel System Requirements, Natural Gas (50Hz)
(Conversions: Cubic feet of Natural Gas/2.644 = Cubic Feet of LPG and Cubic Feet of LPG/8.533 = Gallons of LPG per hour - estimated)
Fuel Consumption, 1/4 Load3044 cu.ft/hr (2395 BTU/Hp-hr)1789 cu.ft/hr (1408 BTU/Hp-hr)4048 cu.ft/hr (3704 BTU/Hp-hr)2435 cu.ft/hr (1916 BTU/Hp-hr)2606 cu.ft/hr (2051 BTU/Hp-hr)
Fuel Consumption, 1/2 Load3539 cu.ft/hr (2785 BTU/Hp-hr)3280 cu.ft/hr (2581 BTU/Hp-hr)4707 cu.ft/hr (3704 BTU/Hp-hr)4464 cu.ft/hr (3513 BTU/Hp-hr)4778 cu.ft/hr (3760 BTU/Hp-hr)
Fuel Consumption, 3/4 Load4115 cu.ft/hr (3239 BTU/Hp-hr)4274 cu.ft/hr (3363 BTU/Hp-hr)5473 cu.ft/hr (4307 BTU/Hp-hr)5816 cu.ft/hr (4577 BTU/Hp-hr)6226 cu.ft/hr (4900 BTU/Hp-hr)
Fuel Consumption, Full Load4785 cu.ft/hr (3766 BTU/Hp-hr)4969 cu.ft/hr (3911 BTU/Hp-hr)6364 cu.ft/hr (5008 BTU/Hp-hr)6763 cu.ft/hr (5323 BTU/Hp-hr)7239 cu.ft/hr (5697 BTU/Hp-hr)
Fuel System Requirements, Natural Gas (60Hz)
(Conversions: Cubic feet of Natural Gas/2.644 = Cubic Feet of LPG and Cubic Feet of LPG/8.533 = Gallons of LPG per hour - estimated)
Fuel Consumption, 1/4 Load2106 cu.ft/hr (1657 BTU/Hp-hr)2187 cu.ft/hr (3155 BTU/Hp-hr)2801 cu.ft/hr (2204 BTU/Hp-hr)2976 cu.ft/hr (2342 BTU/Hp-hr)3186 cu.ft/hr (2507 BTU/Hp-hr)
Fuel Consumption, 1/2 Load3861 cu.ft/hr (3039 BTU/Hp-hr)4010 cu.ft/hr (3155 BTU/Hp-hr)5135 cu.ft/hr (4041 BTU/Hp-hr)5457 cu.ft/hr (4295 BTU/Hp-hr)5841 cu.ft/hr (4597 BTU/Hp-hr)
Fuel Consumption, 3/4 Load5031 cu.ft/hr (3959 BTU/Hp-hr)5225 cu.ft/hr (4112 BTU/Hp-hr)6691 cu.ft/hr (5266 BTU/Hp-hr)7110 cu.ft/hr (5596 BTU/Hp-hr)7611 cu.ft/hr (5990 BTU/Hp-hr)
Fuel Consumption, Full Load5850 cu.ft/hr (4604 BTU/Hp-hr)6075 cu.ft/hr (4781 BTU/Hp-hr)7780 cu.ft/hr (6123 BTU/Hp-hr)8268 cu.ft/hr (6507 BTU/Hp-hr)8850 cu.ft/hr (6965 BTU/Hp-hr)
Heat Exchanger Cooling System Requirements (50Hz)
Minimum Raw Water Flow (City Water)Consult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Maximum Supply Water Temperature (F°)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)
Heat Exchanger Cooling System Requirements (60Hz)
Minimum Raw Water Flow (City Water)Consult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Maximum Supply Water Temperature (F°)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)
Remote Cooling System Requirements (50Hz)
Maximum Coolant Static Head60 ft (18 m)60 ft (18 m)60 ft (18.3 m)60 ft (18.3 m)60 ft (18.3 m)
Ventilation Required (Based on 25F° Temperature Rise)11,782 cfm (207 lps)12,492 cfm (219 lps)14,694 cfm (258 lps)15,822 cfm (278 lps)17,063 cfm (300 lps)
Remote Cooling System Requirements (60Hz)
Maximum Coolant Static Head60 ft (18 m)60 ft (18 m)60 ft (18.3 m)60 ft (18.3 m)60 ft (18.3 m)
Ventilation Required (Based on 25F° Temperature Rise)13,751 cfm (242 lps)14,392 cfm (253 lps)17,544 cfm (308 lps)18,806 cfm (330 lps)20,243 cfm (356 lps)
Dimensions (Open Unit Configuration -- Accessories Not Included)
Length168 in (4267 mm)168 in (4267 mm)172 in (4369 mm)172 in (4369 mm)172 in (4369 mm)
Width95 in (2413 mm)95 in (2413 mm)91 in (2311 mm)91 in (2311 mm)91 in (2311 mm)
Height96 in (2438 mm)96 in (2438 mm)105 in (2667 mm)105 in (2667 mm)105 in (2667 mm)
Weight16,283 lbs (7385 Kg)16,632 lbs (7544 Kg)16,859 lbs (4667 Kg)16,859 lbs (4667 Kg)17,224 lbs (7813 Kg)
Cubes (Approximate)886 ft886 ft950 ft950 ft950 ft
Control Panel Options and Accessories
High Coolant Temperature Pre-Alarm
Low Oil Pressure Pre-Alarm
Alarm Horn with Switch
Remote Start-Stop
Remote Annunciator
Run Relay (Per NFPA 110)
Dry Contacts (Per NFPA 110)
Engine Exhaust System Options and Accessories
Industrial Silencer
Residential Silencer
Critical Silencer
Exhaust Flex
Rain Cap
Generator Options and Accessories
Main Line Circuit Breaker
Shunt Trip
Alternator Heater
Field Circuit Breaker
PMG
Engine Electrical System Options and Accessories
Batteries
Battery Rack
Battery Cables
Battery Charger (Automatic)
Battery Charger (Trickle)
Engine Fuel System Options and Accessories
Flexible Fuel Lines
Miscellaneous Options and Accessories
Weather-Protective Enclosure
Sound-Attentuated Enclosure
Vibration Isolators
Coolant Heater
NOTES:
Standby Ratings: Standby ratings are applicable for supplying emergency power for the duration of a utility power outage. Primary power to the installation is utility supplied. No overload capability for standby rating. Standby ratings in accordance with ISO 3046, BS 55114, DIN 6271.
Continuous Power Rating: Continuous power is the maximum power available for continuous duty. A 10% overload capacity is available for 1 hour out of 12 hours of operation. Prime Power ratings in accordance with ISO 3046, BS55114, DIN 6271.
For additional information, please consult Tele-Lite.
Manufacturer reserves the right to implement specifications or design changes without notice.

MODEL (Click Name For PDF)TLIGLC750N-CTLIGLC800N-CTLIGLC880N-C
Gen Set RatingsClick for RatingsClick for RatingsClick for Ratings
Features
Large Backlit LCD with Alpha-Numeric Readout
Microprocessor-Based Design
16 Programmable Alarms/Shutdowns Set Points
4 Programmable Inputs
Alarm Horn
Not-In-Automatic Alarm
Digital Three Phase Voltage And Current Monitoring
Password-Protected Front Panel Programming
4 Programmable Outputs
Local Emergency Stop Switch
Optional NFPA 110 Level I
Digital Oil Pressure Gauge
Digital Water Temperature Gauge
Digital Battery Voltmeter
Overspeed Shutdown
Emergency Stop Shutdown
Loss Of Speed Signal
Overcrank Shutdown
Designed To Meet/Exceed UL 508, UL 2200, NFPA 70 and NFPA 110 Standards
Engine Technical Data
ManufacturerCumminsCumminsCummins
ModelGTA50-G1GTA50-G2GTA50-G3
Type4 Cycle4 Cycle4 Cycle
Configuration16 Cylinders, 60°-V16 Cylinders, 60°-V16 Cylinders, 60°-V
AspirationTurbocharged, After-CooledTurbocharged, After-CooledTurbocharged, After-Cooled
Displacement3067 cu. in. (50.3 liters)3067 cu. in. (50.3 liters)3067 cu. in. (50.3 liters)
Bore and Stroke6.25" x 6.25"
(159 mm x 159 mm)
6.25" x 6.25"
(159 mm x 159 mm)
6.25" x 6.25"
(159 mm x 159 mm)
Compression Ratio8.5:18.5:18.5:1
Air Filter TypeDryDryDry
Governor TypeElectronicElectronicElectronic
Govenor ModelWoodward FlowtechWoodward FlowtechWoodward Flowtech
Injection Pump Type/Model75 mm75 mm75 mm
Frequency Regulation, Steady State±0.25%±0.25%±0.25%
Frequency Regulation, No Load to Full LoadIsochronousIsochronousIsochronous
Battery Voltage24V DC24V DC24V DC
Water Pump TypeCentrifugalCentrifugalCentrifugal
Coolant Capacity - Radiator CooledTBATBATBA
Coolant Capacity - Engine Only162 qts (153 liters)162 qts (153 liters)162 qts (153 liters)
Oil Pan Capacity 204-174 gals (54-46 liters)204-174 gals (54-46 liters)204-174 gals (54-46 liters)
Recommended Oil Type (SF/CC/CD -10°F to 90°F)10W-4010W-4010W-40
Engine Operational Values (50Hz)
Maximum Ambient Temperature100° F (38° C)100° F (38° C)100° F (38° C)
Heat Rejected to Coolant39,900 Btu/min (701 kWm)41,430 Btu/min (728 kWm)44,502 Btu/min (782 kWm)
Heat Rejected to Aftercooler3675 Btu/min (65 kWm)4360 Btu/min (77 kWm)5790 Btu/min (102 kWm)
Maximum Power at Rated RPM958 BHP/min (715 kWm)1016 BHP/min (758 kWm)1144 BHP/min (853 kWm)
Coolant Flow325 gpm (1230 lpm)325 gpm (1230 lpm)325 gpm (1230 lpm)
Exhaust Temperature1350° F (732° C)1350° F (732° C)1350° F (732° C)
Exhaust Flow7164 cfm (3381 m³/min)4928 cfm (2326 m³/min)5419 cfm (2558 m³/min)
Gas Pressure Required10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)
Minimum Pipe Size at Engine2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)
Normal Oil Pressure (High)50-70 PSI (345-483 kPa)50-70 PSI (345-483 kPa)50-70 PSI (345-483 kPa)
Engine Operational Values (60Hz)
Maximum Ambient Temperature100° F (38° C)100° F (38° C)100° F (38° C)
Heat Rejected to Coolant46,223 Btu/min (812 kWm)50,100 Btu/min (880 kWm)53,300 Btu/min (639 kWm)
Heat Rejected to Aftercooler6950 Btu/min (122 kWm)7900 Btu/min (139 kWm)9433 Btu/min (166 kWm)
Maximum Power at Rated RPM1150 BHP/min (858 kWm)1220 BHP/min (910 kWm)1334 BHP/min (995 kWm)
Coolant Flow390 gpm (1476 lpm)390 gpm (1476 lpm)390 gpm (1476 lpm)
Exhaust Temperature1350° F (732° C)1350° F (732° C)1350° F (732° C)
Exhaust Flow8266 cfm (3902 m³/min)6288 cfm (2968 m³/min)5753 cfm (2715 m³/min)
Gas Pressure Required10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)10-20 in. H2O (254-508 mm H2O)
Minimum Pipe Size at Engine2 in. (51 mm)2 in. (51 mm)2 in. (51 mm)
Normal Oil Pressure (High)50-70 PSI (345-483 kPa)50-70 PSI (345-483 kPa)50-70 PSI (345-483 kPa)
Alternator Technical Data
Generator Frame666
ExciterBrushlessBrushlessBrushless
Cooling FanCast Alloy AluminumCast Alloy AluminumCast Alloy Aluminum
BearingSingle, Double-ShieldedSingle, Double-ShieldedSingle, Double-Shielded
Connection TypeReconnectableReconnectableReconnectable
Insulation TypeClass HClass HClass H
Windings100% Copper100% Copper100% Copper
Pitch2/32/32/3
Amortisseur WindingFullFullFull
Voltage RegulatorMX321MX321MX321
Voltage Regulation (NL - FL)0.50%0.50%0.50%
Underspeed ProtectionStandardStandardStandard
Overexcitation ProtectionStandardStandardStandard
Overvoltage ProtectionStandardStandardStandard
Loss of Sensing ProtectionStandardStandardStandard
Overspeed2250 RPM2250 RPM2250 RPM
StandardsNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BSNEMA, IEC, IEEE, CSA, BS
Phase SequenceA(U), B(V), C(W)A(U), B(V), C(W)A(U), B(V), C(W)
TIF (1960 Weightings)<50<50<50
Excitation SystemPMG StandardPMG StandardPMG Standard
Alternator Performance DataClick for DataClick for DataClick for Data
Ventilation Requirements (50Hz)
a. Cooling Airflow Required (Unit-Mounted Radiator)75,000 cfm (35,400 l/s)75,000 cfm (35,400 l/s)75,000 cfm (35,400 l/s)
b. Combustion Air Required16557 cfm (782 l/s)1761 cfm (831 l/s)1960 cfm (925 l/s)
Total Ventilation Requirements (a. + b.)76,657 cfm (36,182 l/s)76,761 cfm (36,231 l/s)76,960 cfm (36,325 l/s)
Maximum Cooling Air Restriction0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)
Recommended Minimum Intake Louver Size (Based on "Free Area")75 ft² (7.0 m²)75 ft² (7.0 m²)75 ft² (7.0 m²)
a. Heat Rejected To Ambient, Engine4474 Btu/min (79 kWm)4695 Btu/min (82 kWm)5242 Btu/min (92 kWm)
b. Heat Rejected To Ambient, Generator4068 Btu/min (71 kWm)4314 Btu/min (76 kWm)4858 Btu/min (85 kWm)
Total Heat Rejection To Ambient (a. + b.)8542 Btu/min (150 kWm)9009 Btu/min (158 kWm)10,100 Btu/min (177 kWm)
Ventilation Requirements (60Hz)
a. Cooling Airflow Required (Unit-Mounted Radiator)75,000 cfm (35,400 l/s)75,000 cfm (35,400 l/s)75,000 cfm (35,400 l/s)
b. Combustion Air Required2083 cfm (983 l/s)2193 cfm (1035 l/s)2358 cfm (1113 l/s)
Total Ventilation Requirements (a. + b.)77,083 cfm (36,383 l/s)77,193 cfm (36,435 l/s)77,358 cfm (36,513 l/s)
Maximum Cooling Air Restriction0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)0.5 in. H20 (12.8 mm H20)
Recommended Minimum Intake Louver Size (Based on "Free Area")75 ft² (7.0 m²)75 ft² (7.0 m²)75 ft² (7.0 m²)
a. Heat Rejected To Ambient, Engine5332 Btu/min (94 kWm)5632 Btu/min (99 kWm)6124 Btu/min (108 kWm)
b. Heat Rejected To Ambient, Generator4883 Btu/min (86 kWm)5180 Btu/min (91 kWm)5664 Btu/min (100 kWm)
Total Heat Rejection To Ambient (a. + b.)10,215 Btu/min (109 kWm)10,812 Btu/min (190 kWm)11,788 Btu/min (207 kWm)
Exhaust System Requirements (50Hz)
Exhaust Gas Flow7164 cfm (3381 m³/min)4928 cfm (2326 m³/min)5419 cfm (2558 m³/min)
Exhaust Temperature (Dry Manifold)1350° F (732° C)1350° F (732° C)1350° F (732° C)
Maximum Back Pressure (Inclusive of Silencer)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)
Exhaust Outlet Size6 in. (152.4 mm)6 in. (152.4 mm)6 in. (152.4 mm)
Emissions, NOxConsult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Emissions, HC
Emissions, CO
Exhaust System Requirements (60Hz)
Exhaust Gas Flow8266 cfm (3902 m³/min)6288 cfm (2968 m³/min)5753 cfm (2715 m³/min)
Exhaust Temperature (Dry Manifold)1350° F (732° C)1350° F (732° C)1350° F (732° C)
Maximum Back Pressure (Inclusive of Silencer)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)2 in. hg (50.8 mm hg)
Exhaust Outlet Size6 in. (152.4 mm)6 in. (152.4 mm)6 in. (152.4 mm)
Emissions, NOx1.91 g/hp-hr1.91 g/hp-hr1.91 g/hp-hr
Emissions, HC17.3 g/hp-hr17.3 g/hp-hr17.3 g/hp-hr
Emissions, CO4.74 g/hp-hr4.74 g/hp-hr4.74 g/hp-hr
Fuel System Requirements, Natural Gas (50Hz)
(Conversions: Cubic feet of Natural Gas/2.644 = Cubic Feet of LPG and Cubic Feet of LPG/8.533 = Gallons of LPG per hour - estimated)
Fuel Consumption, 1/4 Load2974 cu.ft/hr (2341 BTU/Hp-hr)3142 cu.ft/hr (2472 BTU/Hp-hr)3416 cu.ft/hr (2688 BTU/Hp-hr)
Fuel Consumption, 1/2 Load5453 cu.ft/hr (4291 BTU/Hp-hr)5759 cu.ft/hr (4533 BTU/Hp-hr)6263 cu.ft/hr (4929 BTU/Hp-hr)
Fuel Consumption, 3/4 Load7105 cu.ft/hr (5592 BTU/Hp-hr)7505 cu.ft/hr (5906 BTU/Hp-hr)8160 cu.ft/hr (6422 BTU/Hp-hr)
Fuel Consumption, Full Load8262 cu.ft/hr (6502 BTU/Hp-hr)8726 cu.ft/hr (6868 BTU/Hp-hr)9489 cu.ft/hr (7468 BTU/Hp-hr)
Fuel System Requirements, Natural Gas (60Hz)
(Conversions: Cubic feet of Natural Gas/2.644 = Cubic Feet of LPG and Cubic Feet of LPG/8.533 = Gallons of LPG per hour - estimated)
Fuel Consumption, 1/4 Load3636 cu.ft/hr (2862 BTU/Hp-hr)3840 cu.ft/hr (3022 BTU/Hp-hr)4176 cu.ft/hr (3287 BTU/Hp-hr)
Fuel Consumption, 1/2 Load6666 cu.ft/hr (5246 BTU/Hp-hr)7041 cu.ft/hr (5541 BTU/Hp-hr)7656 cu.ft/hr (6025 BTU/Hp-hr)
Fuel Consumption, 3/4 Load8686 cu.ft/hr (6836 BTU/Hp-hr)9174 cu.ft/hr (7220 BTU/Hp-hr)9976 cu.ft/hr (7851 BTU/Hp-hr)
Fuel Consumption, Full Load10,100 cu.ft/hr (7949 BTU/Hp-hr)10,668 cu.ft/hr (8396 BTU/Hp-hr)11,600 cu.ft/hr (9129 BTU/Hp-hr)
Heat Exchanger Cooling System Requirements (50Hz)
Minimum Raw Water Flow (City Water)Consult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Maximum Supply Water Temperature (F°)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)
Heat Exchanger Cooling System Requirements (60Hz)
Minimum Raw Water Flow (City Water)Consult Tele-LiteConsult Tele-LiteConsult Tele-Lite
Maximum Supply Water Temperature (F°)80° F (12.44° C)80° F (12.44° C)80° F (12.44° C)
Remote Cooling System Requirements (50Hz)
Maximum Coolant Static Head60 ft (18.3 m)60 ft (18.3 m)60 ft (18.3 m)
Ventilation Required (Based on 25F° Temperature Rise)18,982 cfm (333 lps)20,020 cfm (352 lps)22,444 cfm (394 lps)
Remote Cooling System Requirements (60Hz)
Maximum Coolant Static Head60 ft (18.3 m)60 ft (18.3 m)60 ft (18.3 m)
Ventilation Required (Based on 25F° Temperature Rise)22,700 cfm (399 lps)24,028 cfm (422 lps)26,197 cfm (460 lps)
Dimensions (Open Unit Configuration -- Accessories Not Included)
Length191 in (4851 mm)191 in (4851 mm)195 in (4953 mm)
Width96 in (2438 mm)96 in (2438 mm)96 in (2438 mm)
Height120 in (3048 mm)120 in (3048 mm)120 in (3048 mm)
Weight20,314 lbs (9214 Kg)21,054 lbs (9550 Kg)21,716 lbs (9850 Kg)
Cubes (Approximate)1275 ft1275 ft1300 ft
Control Panel Options and Accessories
High Coolant Temperature Pre-Alarm
Low Oil Pressure Pre-Alarm
Alarm Horn with Switch
Remote Start-Stop
Remote Annunciator
Run Relay (Per NFPA 110)
Dry Contacts (Per NFPA 110)
Engine Exhaust System Options and Accessories
Industrial Silencer
Residential Silencer
Critical Silencer
Exhaust Flex
Rain Cap
Generator Options and Accessories
Main Line Circuit Breaker
Shunt Trip
Alternator Heater
Field Circuit Breaker
PMG
Engine Electrical System Options and Accessories
Batteries
Battery Rack
Battery Cables
Battery Charger (Automatic)
Battery Charger (Trickle)
Engine Fuel System Options and Accessories
Flexible Fuel Lines
Miscellaneous Options and Accessories
Weather-Protective Enclosure
Sound-Attentuated Enclosure
Vibration Isolators
Coolant Heater
NOTES:
Standby Ratings: Standby ratings are applicable for supplying emergency power for the duration of a utility power outage. Primary power to the installation is utility supplied. No overload capability for standby rating. Standby ratings in accordance with ISO 3046, BS 55114, DIN 6271.
Continuous Power Rating: Continuous power is the maximum power available for continuous duty. A 10% overload capacity is available for 1 hour out of 12 hours of operation. Prime Power ratings in accordance with ISO 3046, BS55114, DIN 6271.
For additional information, please consult Tele-Lite.
Manufacturer reserves the right to implement specifications or design changes without notice.
   April  26, 2024