| Back To Home > Baldor Generators > Industrial Agricultural Standby -- Diesel Liquid-Cooled (DLC) |
INDUSTRIAL AGRICULTURAL STANDBY -- DIESEL LIQUID-COOLED (DLC) |
|
All Baldor Industrial Agricultural Standby generators are prototype engineered, factory built
and production tested. They feature:
- Ratings from 30 kW to 200 kW. (Larger diesel ratings up to 2000 kW are available. See IDLC product line.)
- Available options - 100-600 amp NEMA 1/NEMA 3R Automatic Transfer Switches, weather enclosures, sub base tanks and circuit breaker.
- 12V DC electric start.
- 100% full load tested for 100% block loading.
- John Deere industrial diesel engine.
- Full status monitor provides system monitoring of low oil pressure, high coolant temperature, overspeed and overcrank.
- Direct fuel line connections for use with existing tanks or provisions for optional sub-base tank. Optional flexible fuel lines available.
- 1800 RPM, 60 HZ, single phase, 4 lead generators.
- Alternators are efficient brushless synchronous four-pole construction, dynamically balanced with double sealed prelubricated ball bearings.
|
|
|
| MODEL (Click Name For PDF) | TLDLC30-JD | TLDLC50-JD | TLDLC60-JD | TLDLC75-JD |
| Gen Set Ratings |
| kW Rating Standby | 30 | 50 | 60 | 75 |
| Voltage Delta | 240/120 | 240/120 | 240/120 | 240/120 |
| Number of Leads | 4 | 4 | 4 | 4 |
| Phase | 1 | 1 | 1 | 1 |
| Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
| Power Factor | 1 | 1 | 1 | 1 |
| Features |
| NEMA 1 Type Enclosure, Vibration Isolated |  |  |  |  |
| Hinged Front Access Allow Easy Access to Wiring |  |  |  |  |
| 3.5" AC Meters with ±2% Accuracy |  |  |  |  |
| Ammeter/Voltmeter Selector Switch for Monitoring Line Voltage and Current in Each Phase |  |  |  |  |
| AC Meters Comply with ANSI C39.1 and IP H2 |  |  |  |  |
| Engine Gauges Comply ith SAE Specifications |  |  |  |  |
| Engine Oil Pressure Gauge |  |  |  |  |
| Engine Coolant Temperature Gauge |  |  |  |  |
| Engine Battery Voltmeter |  |  |  |  |
| Engine Operating Hours |  |  |  |  |
| Low Oil Pressure Shutdown with Indicator |  |  |  |  |
| High Coolant Temperature Shutdown with Indicator |  |  |  |  |
| Engine Over-Speed Shutdown with Indicator |  |  |  |  |
| Engine Over-Crank Shutdown with Indicator |  |  |  |  |
| Engine Running Indicator |  |  |  |  |
| AC Voltmeter |  |  |  |  |
| AC Ammeter |  |  |  |  |
| AC Frequency |  |  |  |  |
| Designed To Meet/Exceed UL 508 and UL 2200 Standards |  |  |  |  |
| Operating Temperature Range -40°C to +85°C |  |  |  |  |
| Engine Technical Data |
| Manufacturer | John Deere | John Deere | John Deere | John Deere |
| Model | PE4045TF150 | PE4045TF150 | PE4045TF150 | PE4045TF250 |
| Type | 4 Cycle | 4 Cycle | 4 Cycle | 4 Cycle |
| Configuration | 4 Cylinders, In-Line | 4 Cylinders, In-Line | 4 Cylinders, In-Line | 4 Cylinders, In-Line |
| Horsepower | 71 | 100 | 100 | 122 |
| Aspiration | Natural | Turbocharged | Turbocharged | Turbocharged |
| Displacement | 276 cu. in. (4.5 liters) | 276 cu. in. (4.5 liters) | 276 cu. in. (4.5 liters) | 276 cu. in. (4.5 liters) |
| Bore and Stroke | 4.19" x 5" (106 mm x 127 mm) | 4.19" x 5" (106 mm x 127 mm) | 4.19" x 5" (106 mm x 127 mm) | 4.19" x 5" (106 mm x 127 mm) |
| Compression Ratio | 17.6:1 | 17.0:1 | 17.0:1 | 17.0:1 |
| Air Filter Type | Dry | Dry | Dry | Dry |
| Governor Type | Mechanical | Mechanical | Mechanical | Mechanical |
| Governor Model | Stanadyne | Stanadyne | Stanadyne | Stanadyne |
| Injection Pump Type/Model | Direct Injection | Direct Injection | Direct Injection | Direct Injection |
| Frequency Regulation, Steady State | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Frequency Regulation, No Load to Full Load | 4% Droop (Optional Electronic Governor | 4% Droop (Optional Electronic Governor | 4% Droop (Optional Electronic Governor | 4% Droop (Optional Electronic Governor |
| Battery Voltage | 12V DC | 12V DC | 12V DC | 12V DC |
| Water Pump Type | Centrifugal | Centrifugal | Centrifugal | Centrifugal |
| Coolant Capacity - Radiator Cooled | 4.3 gals (16.3 liters) | 4.3 gals (16.3 liters) | 4.3 gals (16.3 liters) | 4.3 gals (16.3 liters) |
| Coolant Capacity - Engine Only | 2.25 gals (8.5 liters) | 2.3 gals (8.5 liters) | 2.3 gals (8.5 liters) | 2.3 gals (8.5 liters) |
| Oil Pan Capacity | 2.0 gals (7.6 liters) | 3.3 gals (12.3 liters) | 3.3 gals (12.3 liters) | 3.3 gals (12.3 liters) |
| Recommended Oil Type (SF/CC/CD -10°F to 90°F) | 10W-40 | 10W-40 | 10W-40 | 10W-40 |
| Engine Operational Values (60Hz) |
| Maximum Ambient Temperature | 104/122° F (40/50° C) | 104/122° F (40/50° C) | 104/122° F (40/50° C) | 104/122° F (40/50° C) |
| Heat Rejected to Coolant | 1820 Btu/min (32 kWm) | 2445 Btu/min (43 kWm) | 2445 Btu/min (43 kWm) | 2959 Btu/min (52 kWm) |
| Maximum Power at Rated RPM | 71 BHP/min (52.97 kWm) | 100 BHP/min (75 kWm) | 100 BHP/min (75 kWm) | 122 BHP/min (91.01 kWm) |
| Coolant Flow at 1 PSI | 38 gpm (2.4 l/s) | 38 gpm (2.4 l/s) | 38 gpm (2.4 l/s) | 38 gpm (2.4 l/s) |
| Exhaust Temperature | 1130° F (595° C) | 946° F (508° C) | 946° F (508° C) | 1026° F (552° C) |
| Exhaust Flow | 318 cfm (150 m³/min) | 480 cfm (227 m³/min) | 480 cfm (227 m³/min) | 614 cfm (290 m³/min) |
| Normal Oil Pressure (Low/High) | 15/50 PSI (105/345 kPa) | 15/50 PSI (105/345 kPa) | 15/50 PSI (105/345 kPa) | 15/50 PSI (105/345 kPa) |
| Maximum Fuel Flow to Injection Pump | 30 gph (96 kg/hr) | 30 gph (96 kg/hr) | 30 gph (96 kg/hr) | 30 gph (96 kg/hr) |
| Alternator Technical Data |
| Generator Frame | 2 | 2 | 2 | 2 |
| Exciter | Brushless | Brushless | Brushless | Brushless |
| Cooling Fan | Cast Alloy Aluminum | Cast Alloy Aluminum | Cast Alloy Aluminum | Cast Alloy Aluminum |
| Bearing | Single, Double-Shielded | Single, Double-Shielded | Single, Double-Shielded | Single, Double-Shielded |
| Connection Type | Reconnectable | Reconnectable | Reconnectable | Reconnectable |
| Insulation Type | Class H | Class H | Class H | Class H |
| Windings | 100% Copper | 100% Copper | 100% Copper | 100% Copper |
| Pitch | 2/3 | 2/3 | 2/3 | 2/3 |
| Amortisseur Winding | Full | Full | Full | Full |
| Voltage Regulator | SA465 | SA465 | SA465 | SA465 |
| Voltage Regulation (NL - FL) | ±1% | ±1% | ±1% | ±1% |
| Underspeed Protection | Standard | Standard | Standard | Standard |
| Overexcitation Protection | Optional | Optional | Optional | Optional |
| Overvoltage Protection | Optional | Optional | Optional | Optional |
| Loss of Sensing Protection | Standard | Standard | Standard | Standard |
| Overspeed | 2250 RPM | 2250 RPM | 2250 RPM | 2250 RPM |
| Standards | NEMA, IEC, IEEE, CSA, BS | NEMA, IEC, IEEE, CSA, BS | NEMA, IEC, IEEE, CSA, BS | NEMA, IEC, IEEE, CSA, BS |
| Phase Sequence | A(U), B(V), C(W) | A(U), B(V), C(W) | A(U), B(V), C(W) | A(U), B(V), C(W) |
| TIF (1960 Weightings) | <50 | <50 | <50 | <50 |
| Excitation System | PMG -- N/A | PMG -- N/A | PMG -- N/A | PMG -- N/A |
| Alternator Performance Data |
| Temperature Rise By Resistance (Stand-By) | 150/40° C | 150/40° C | 150/40° C | 150/40° C |
| Generator Model Number | UCI224C | UCI224D | UCI224F | UCI224G |
| Generator kW at 150/125/105° C/40° C Ambient (240/120V, 1P) | 43/37.5/33.8 | 50/44/40 | 69/60/56.9 | 86/75/65.6 |
| SKVA Output with 30% Voltage Dip Maximum, 100% Recovery at 60 Hz | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite |
| Maximum SKVA at 90% Sustained Voltage Dip | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite |
| Subtransient Reactance at Voltage Listed | 17% | 17% | 14% | 14% |
| Line - Line Harmonic Maximum Total | 5.00% | 5.00% | 5.00% | 5.00% |
| Ventilation Requirements (60Hz) |
| a. Cooling Airflow Required (Unit-Mounted Radiator) | 2597 cfm (1226 l/s) | 3861 cfm (1822 l/s) | 5553 cfm (2620 l/s) | 5342 cfm (2521 l/s) |
| b. Combustion Air Required | 103 cfm (49 l/s) | 191 cfm (90 l/s) | 206 cfm (97 l/s) | 293 cfm (139 l/s) |
| Total Ventilation Requirements (a. + b.) | 2700 cfm (1275 l/s) | 4052 cfm (1912 l/s) | 5759 cfm (2717 l/s) | 5653 cfm (2660 l/s) |
| Maximum Cooling Air Restriction | 1.5 in.H20 (1.137 in.hg) | 1.5 in.H20 (1.137 in.hg) | 0.5 in.H20 (0.037 in.hg) | 0.5 in.H20 (0.037 in.hg) |
| Recommended "Free Area" Intake Louver Size | 6.3 ft² (0.585 m²) | 6.3 ft² (0.585 m²) | 6.3 ft² (0.585 m²) | 6.3 ft² (0.585 m²) |
| a. Heat Rejected To Ambient, Engine | 500 Btu/min (9 kWm) | 2450 Btu/min (43 kWm) | 1045 Btu/min (18.3 kWm) | 918 Btu/min (16 kWm) |
| b. Heat Rejected To Ambient, Generator | 114 Btu/min (2 kWm) | 142 Btu/min (2.5 kWm) | 171 Btu/min (3 kWm) | 227 Btu/min (4 kWm) |
| Total Heat Rejection To Ambient (a. + b.) | 614 Btu/min (10.8 kWm) | 2592 Btu/min (46 kWm) | 1216 Btu/min (21.3 kWm) | 1146 Btu/min (20 kWm) |
| Exhaust System Requirements (60Hz) |
| Exhaust Gas Flow | 318 cfm (150 l/s) | 480 cfm (227 l/s) | 480 cfm (227 l/s) | 614 cfm (290 l/s) |
| Exhaust Temperature (Dry Manifold) | 1130° F (595° C) | 946° F (508° C) | 946° F (508° C) | 1026° F (552° C) |
| Maximum Back Pressure (Inclusive of Silencer) | 3.0 in.hg (41.0 kPa) | 3.0 in.hg (41.0 kPa) | 3 in.hg (41.0 kPa) | 3 in.hg (41.0 kPa) |
| Exhaust Outlet Size | 2.5 in. (63.5 mm) | 4 in. (101.6 mm) | 4 in. (101.6 mm) | 4 in. (101.6 mm) |
| Emissions, NOx | Meets EPA Tier One/CARB Consult Tele-Lite for Actual Values | Meets EPA Tier One/CARB Consult Tele-Lite for Actual Values | Meets EPA Tier One/CARB Consult Tele-Lite for Actual Values | Meets EPA Tier One/CARB Consult Tele-Lite for Actual Values |
| Emissions, HC |
| Emissions, CO |
| Emissions, Particulates - PM |
| Fuel System Requirements (60Hz) |
| Fuel Consumption, 1/4 Load | 1.2 gph (4.4 Lph) | 1.7 gph (6.3 Lph) | 1.7 gph (6.3 Lph) | 1.8 gph (6.9 Lph) |
| Fuel Consumption, 1/2 Load | 2.0 gph (7.7 Lph) | 2.7 gph (10.2 Lph) | 2.7 gph (10.2 Lph) | 3.3 gph (12.6 Lph) |
| Fuel Consumption, 3/4 Load | 2.9 gph (10.8 Lph) | 3.8 gph (14.4 Lph) | 3.8 gph (14.4 Lph) | 4.8 gph (18.0 Lph) |
| Fuel Consumption, Full Load | 3.7 gph (13.9 Lph) | 4.9 gph (18.6 Lph) | 4.9 gph (18.6 Lph) | 6.2 gph (23.5 Lph) |
| Heat Exchanger Cooling System Requirements (60Hz) |
| Minimum Raw Water Flow (City Water) | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite |
| Maximum Supply Water Temperature | 80° F (12.44 ° C) | 80° F (12.44 ° C) | 80° F (12.44 ° C) | 80° F (12.44 ° C) |
| Remote Cooling System Requirements (60Hz) |
| Maximum Coolant Static Head | 46 ft (14 m) | 46 ft (14 m) | 46 ft (14 m) | 46 ft (14 m) |
| Ventilation Required (Based on 25° F Temperature Rise) | 1364 cfm (24 lps) | 5760 cfm (102 lps) | 2702 cfm (47 lps) | 2547 cfm (44 lps) |
| Dimensions (Open Unit Configuration -- Accessories Not Included) |
| Length | 84 in. (2134 mm) | 84 in. (2134 mm) | 84 in. (2134 mm) | 84 in. (2134 mm) |
| Width | 42.0 in. (1067 mm) | 42.0 in. (1067 mm) | 42.0 in. (1067 mm) | 42.0 in. (1067 mm) |
| Height | 45.0 in. (1143 mm) | 45.0 in. (1143 mm) | 45.0 in. (1143 mm) | 45.0 in. (1143 mm) |
| Weight | 2200 lbs (998 Kg) | 2200 lbs (998 Kg) | 2200 lbs (998 Kg) | 2200 lbs (998 Kg) |
| Cubes (Approximate) | 80.9 ft | 80.9 ft | 80.9 ft | 80.9 ft |
| Control Panel Options and Accessories |
| Run Relay (10 Amp) |  |  |  |  |
| Dry Contacts for Alarms |  |  |  |  |
| Remote E-Stop |  |  |  |  |
| Remote Annunciator |  |  |  |  |
| Engine Exhaust System Options and Accessories |
| Industrial Silencer |  |  |  |  |
| Critical Silencer |  |  |  |  |
| Exhaust Flex |  |  |  |  |
| Exhaust Extension |  |  |  |  |
| Rain Cap |  |  |  |  |
| Generator Options and Accessories |
| Main Line Circuit Breaker |  |  |  |  |
| Space Heater |  |  |  |  |
| Engine Electrical System Options and Accessories |
| Batteries |  |  |  |  |
| Battery Rack |  |  |  |  |
| Battery Cables |  |  |  |  |
| Battery Charger (Automatic) |  |  |  |  |
| Engine Fuel System Options and Accessories |
| Sub-Base Fuel Tank |  |  |  |  |
| Flexible Fuel Lines |  |  |  |  |
| Miscellaneous Options and Accessories |
| Weather-Protective Enclosure |  |  |  |  |
| Coolant Heater |  |  |  |  |
NOTES: For ratings and voltages not listed above consult Tele-Lite.
Standby ratings do not have an overload capability but can be used for the duration of the utility failure per ISO-3046, DIN6271 and BS5514.
Base load (continuous) ratings are continuous per DIN 6271, BS 5514 and ISO-8528 with no sustained overload capacity.
Consult factory for base load ratings.
Altitude derate is 4% for each 1000 feet over 5000.
Temperature derate is 1% for 10°F over 100°F ambient. |
| MODEL (Click Name For PDF) | TLDLC100-JD | TLDLC125-JD | TLDLC150-JD | TLDLC200-JD |
| Gen Set Ratings |
| kW Rating Standby | 100 | 125 | 150 | 200 |
| Voltage Delta | 240/120 | 240/120 | 240/120 | 240/120 |
| Number of Leads | 4 | 4 | 4 | 4 |
| Phase | 1 | 1 | 1 | 1 |
| Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
| Power Factor | 1 | 1 | 1 | 1 |
| Features |
| NEMA 1 Type Enclosure, Vibration Isolated |  |  |  |  |
| Hinged Front Access Allow Easy Access to Wiring |  |  |  |  |
| 3.5" AC Meters with ±2% Accuracy |  |  |  |  |
| Ammeter/Voltmeter Selector Switch for Monitoring Line Voltage and Current in Each Phase |  |  |  |  |
| AC Meters Comply with ANSI C39.1 and IP H2 |  |  |  |  |
| Engine Gauges Comply ith SAE Specifications |  |  |  |  |
| Engine Oil Pressure Gauge |  |  |  |  |
| Engine Coolant Temperature Gauge |  |  |  |  |
| Engine Battery Voltmeter |  |  |  |  |
| Engine Operating Hours |  |  |  |  |
| Low Oil Pressure Shutdown with Indicator |  |  |  |  |
| High Coolant Temperature Shutdown with Indicator |  |  |  |  |
| Engine Over-Speed Shutdown with Indicator |  |  |  |  |
| Engine Over-Crank Shutdown with Indicator |  |  |  |  |
| Engine Running Indicator |  |  |  |  |
| AC Voltmeter |  |  |  |  |
| AC Ammeter |  |  |  |  |
| AC Frequency |  |  |  |  |
| Designed To Meet/Exceed UL 508 and UL 2200 Standards |  |  |  |  |
| Operating Temperature Range -40°C to +85°C |  |  |  |  |
| Engine Technical Data |
| Manufacturer | John Deere | John Deere | John Deere | John Deere |
| Model | PE6068TF150 | PE6068TF250 | PE6068HF150 | 6081AF001 |
| Type | 4 Cycle | 4 Cycle | 4 Cycle | 4 Cycle |
| Configuration | 6 Cylinders, In-Line | 6 Cylinders, In-Line | 6 Cylinders, In-Line | 6 Cylinders, In-Line |
| Horsepower | 165 | 190 | 251 | 347 |
| Aspiration | Turbocharged | Turbocharged | Turbocharged | Turbocharged |
| Displacement | 414 cu. in. (6.8 liters) | 414 cu. in. (6.8 liters) | 276 cu. in. (4.5 liters) | 276 cu. in. (4.5 liters) |
| Bore and Stroke | 4.19" x 5" (106 mm x 127 mm) | 4.19" x 5" (106 mm x 127 mm) | 4.19" x 5" (106 mm x 127 mm) | 4.56" x 5.06" (116 mm x 129 mm) |
| Compression Ratio | 17.0:1 | 17.0:1 | 17.0:1 | 16.5:1 |
| Air Filter Type | Dry | Dry | Dry | Dry |
| Governor Type | Mechanical | Mechanical | Mechanical | Mechanical |
| Governor Model | Stanadyne | Stanadyne | Stanadyne | RB P7100 |
| Injection Pump Type/Model | Direct Injection | Direct Injection | Direct Injection | Direct Injection |
| Frequency Regulation, Steady State | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Frequency Regulation, No Load to Full Load | 4% Droop (Optional Electronic Governor | 4% Droop (Optional Electronic Governor | 4% Droop (Optional Electronic Governor | 4% Droop (Optional Electronic Governor |
| Battery Voltage | 12V DC | 12V DC | 12V DC | 12V DC |
| Water Pump Type | Centrifugal | Centrifugal | Centrifugal | Centrifugal |
| Coolant Capacity - Radiator Cooled | 4.9 gals (18.5 liters) | 4.9 gals (18.5 liters) | 7.8 gals (29.5 liters) | 16.8 gals (63.4 liters) |
| Coolant Capacity - Engine Only | 3.0 gals (11.4 liters) | 3.0 gals (11.4 liters) | 3.0 gals (11.4 liters) | 4.0 gals (15.1 liters) |
| Oil Pan Capacity | 4.3 gals (16.1 liters) | 4.3 gals (16.1 liters) | 6.3 gals (23.7 liters) | 8.2 gals (31.0 liters) |
| Recommended Oil Type (SF/CC/CD -10°F to 90°F) | 10W-40 | 10W-40 | 10W-40 | 10W-40 |
| Engine Operational Values (60Hz) |
| Maximum Ambient Temperature | 104/122° F (40/50° C) | 104/122° F (40/50° C) | 104/122° F (40/50° C) | 104/122° F (40/50° C) |
| Heat Rejected to Coolant | 3520 Btu/min (62 kWm) | 4324 Btu/min (76 kWm) | 4438 Btu/min (78 kWm) | 8251 Btu/min (145 kWm) |
| Maximum Power at Rated RPM | 165 BHP/min (123.09 kWm) | 190 BHP/min (141.74 kWm) | 251 BHP/min (187.25 kWm) | 347 BHP/min (258.86 kWm) |
| Coolant Flow at 1 PSI | 38 gpm (2.4 l/s) | 46 gpm (2.9 l/s) | 46 gpm (2.9 l/s) | 75 gpm (4.8 l/s) |
| Exhaust Temperature | 1101° F (544° C) | 1112° F (600° C) | 1056° F (569° C) | 927° F (497° C) |
| Exhaust Flow | 787 cfm (371 m³/min) | 918 cfm (433 m³/min) | 1201 cfm (567 m³/min) | 1854 cfm (875 m³/min) |
| Normal Oil Pressure (Low/High) | 15/50 PSI (105/345 kPa) | 15/50 PSI (105/345 kPa) | 15/50 PSI (105/345 kPa) | 15/50 PSI (105/345 kPa) |
| Maximum Fuel Flow to Injection Pump | 30 gph (96 kg/hr) | 30 gph (96 kg/hr) | 30 gph (96 kg/hr) | 30 gph (96 kg/hr) |
| Alternator Technical Data |
| Generator Frame | 2 | 2 | 2 | 2 |
| Exciter | Brushless | Brushless | Brushless | Brushless |
| Cooling Fan | Cast Alloy Aluminum | Cast Alloy Aluminum | Cast Alloy Aluminum | Cast Alloy Aluminum |
| Bearing | Single, Double-Shielded | Single, Double-Shielded | Single, Double-Shielded | Single, Double-Shielded |
| Connection Type | Reconnectable | Reconnectable | Reconnectable | Reconnectable |
| Insulation Type | Class H | Class H | Class H | Class H |
| Windings | 100% Copper | 100% Copper | 100% Copper | 100% Copper |
| Pitch | 2/3 | 2/3 | 2/3 | 2/3 |
| Amortisseur Winding | Full | Full | Full | Full |
| Voltage Regulator | SA465 | SA465 | SA465 | SA465 |
| Voltage Regulation (NL - FL) | ±1% | ±1% | ±1% | ±1% |
| Underspeed Protection | Standard | Standard | Standard | Standard |
| Overexcitation Protection | Optional | Optional | Optional | Optional |
| Overvoltage Protection | Optional | Optional | Optional | Optional |
| Loss of Sensing Protection | Standard | Standard | Standard | Standard |
| Overspeed | 2250 RPM | 2250 RPM | 2250 RPM | 2250 RPM |
| Standards | NEMA, IEC, IEEE, CSA, BS | NEMA, IEC, IEEE, CSA, BS | NEMA, IEC, IEEE, CSA, BS | NEMA, IEC, IEEE, CSA, BS |
| Phase Sequence | A(U), B(V), C(W) | A(U), B(V), C(W) | A(U), B(V), C(W) | A(U), B(V), C(W) |
| TIF (1960 Weightings) | <50 | <50 | <50 | <50 |
| Excitation System | PMG -- N/A | PMG -- N/A | PMG -- N/A | PMG -- N/A |
| Alternator Performance Data |
| Temperature Rise By Resistance (Stand-By) | 150/40° C | 150/40° C | 150/40° C | 150/40° C |
| Generator Model Number | UCI274C | UCI274E | UCI274F | UCI274J |
| Generator kW at 150/125/105° C/40° C Ambient (240/120V, 1P) | 100/90/75 | 132/115/100 | 155/135/125 | 200/175/160 |
| SKVA Output with 30% Voltage Dip Maximum, 100% Recovery at 60 Hz | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite |
| Maximum SKVA at 90% Sustained Voltage Dip | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite |
| Subtransient Reactance at Voltage Listed | 13% | 14% | 12% | 8% |
| Line - Line Harmonic Maximum Total | 5.00% | 5.00% | 5.00% | 5.00% |
| Ventilation Requirements (60Hz) |
| a. Cooling Airflow Required (Unit-Mounted Radiator) | 4983 cfm (2351 l/s) | 8500 cfm (4012 l/s) | 9000 cfm (4247 l/s) | 14,000 cfm (6608 l/s) |
| b. Combustion Air Required | 270 cfm (127 l/s) | 452 cfm (214 l/s) | 550 cfm (259 l/s) | 643 cfm (303 l/s) |
| Total Ventilation Requirements (a. + b.) | 5253 cfm (2478 l/s) | 8952 cfm (4226 l/s) | 9550 cfm (4506 l/s) | 14,643 cfm (6911 l/s) |
| Maximum Cooling Air Restriction | 0.5 in.H20 (0.037 in.hg) | 0.5 in.H20 (0.037 in.hg) | 0.5 in.H20 (0.037 in.hg) | 0.5 in.H20 (0.037 in.hg) |
| Recommended "Free Area" Intake Louver Size | 6.3 ft² (0.585 m²) | 8.95 ft² (0.83 m²) | 12.6 ft² (1.171 m²) | 15.8 ft² (1.468 m²) |
| a. Heat Rejected To Ambient, Engine | 1025 Btu/min (18 kWm) | 2000 Btu/min (35 kWm) | 1850 Btu/min (33 kWm) | 1850 Btu/min (33 kWm) |
| b. Heat Rejected To Ambient, Generator | 285 Btu/min (5 kWm) | 356 Btu/min (6.25 kWm) | 427 Btu/min (7.5 kWm) | 569 Btu/min (10 kWm) |
| Total Heat Rejection To Ambient (a. + b.) | 1310 Btu/min (23 kWm) | 2356 Btu/min (41.25 kWm) | 2277 Btu/min (40.5 kWm) | 2419 Btu/min (43 kWm) |
| Exhaust System Requirements (60Hz) |
| Exhaust Gas Flow | 787 cfm (371 l/s) | 918 cfm (433 l/s) | 1201 cfm (567 l/s) | 1854 cfm (875 l/s) |
| Exhaust Temperature (Dry Manifold) | 1011° F (544° C) | 1112° F (600° C) | 1056° F (569° C) | 927° F (497° C) |
| Maximum Back Pressure (Inclusive of Silencer) | 3.0 in.hg (41.0 kPa) | 3.0 in.hg (41.0 kPa) | 3 in.hg (41.0 kPa) | 3 in.hg (41.0 kPa) |
| Exhaust Outlet Size | 4 in. (101.6 mm) | 4 in. (101.6 mm) | 4 in. (101.6 mm) | 4 in. (101.6 mm) |
| Emissions, NOx | Meets EPA Tier One/CARB Consult Tele-Lite for Actual Values | Meets EPA Tier One/CARB Consult Tele-Lite for Actual Values | Meets EPA Tier One/CARB Consult Tele-Lite for Actual Values | Meets EPA Tier One/CARB Consult Tele-Lite for Actual Values |
| Emissions, HC |
| Emissions, CO |
| Emissions, Particulates - PM |
| Fuel System Requirements (60Hz) |
| Fuel Consumption, 1/4 Load | 2.4 gph (9.1 Lph) | 2.7 gph (10.2 Lph) | 3.3 gph (12.5 Lph) | 4.7 gph (17.7 Lph) |
| Fuel Consumption, 1/2 Load | 4.2 gph (16 Lph) | 4.8 gph (18.3 Lph) | 6.3 gph (23.8 Lph) | 8.5 gph (32.2 Lph) |
| Fuel Consumption, 3/4 Load | 6.3 gph (23.8 Lph) | 7.3 gph (27.5 Lph) | 9.5 gph (36.0 Lph) | 12.5 gph (47.1 Lph) |
| Fuel Consumption, Full Load | 8.2 gph (30.9 Lph) | 9.4 gph (35.7 Lph) | 12.3 gph (46.7 Lph) | 17.1 gph (64.6 Lph) |
| Heat Exchanger Cooling System Requirements (60Hz) |
| Minimum Raw Water Flow (City Water) | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite | Consult Tele-Lite |
| Maximum Supply Water Temperature | 80° F (12.44 ° C) | 80° F (12.44 ° C) | 80° F (12.44 ° C) | 80° F (12.44 ° C) |
| Remote Cooling System Requirements (60Hz) |
| Maximum Coolant Static Head | 46 ft (14 m) | 60 ft (18.3 m) | 60 ft (18.3 m) | 60 ft (18.3 m) |
| Ventilation Required (Based on 25° F Temperature Rise) | 2911 cfm (51 lps) | 5236 cfm (92 lps) | 5060 cfm (90 lps) | 5376 cfm (96 lps) |
| Dimensions (Open Unit Configuration -- Accessories Not Included) |
| Length | 108 in. (2743 mm) | 108 in. (2743 mm) | 108 in. (2743 mm) | 114 in. (2896 mm) |
| Width | 48.0 in. (1219 mm) | 48.0 in. (1219 mm) | 48.0 in. (1219 mm) | 48.0 in. (1219 mm) |
| Height | 56.0 in. (1422 mm) | 56.0 in. (1422 mm) | 56.0 in. (1422 mm) | 58.0 in. (1473 mm) |
| Weight | 2700 lbs (1225 Kg) | 2700 lbs (1225 Kg) | 3300 lbs (1497 Kg) | 3875 lbs (1759 Kg) |
| Cubes (Approximate) | 150.5 ft | 150.5 ft | 155.8 ft | 200 ft |
| Control Panel Options and Accessories |
| Run Relay (10 Amp) |  |  |  |  |
| Dry Contacts for Alarms |  |  |  |  |
| Remote E-Stop |  |  |  |  |
| Remote Annunciator |  |  |  |  |
| Engine Exhaust System Options and Accessories |
| Industrial Silencer |  |  |  |  |
| Critical Silencer |  |  |  |  |
| Exhaust Flex |  |  |  |  |
| Exhaust Extension |  |  |  |  |
| Rain Cap |  |  |  |  |
| Generator Options and Accessories |
| Main Line Circuit Breaker |  |  |  |  |
| Space Heater |  |  |  |  |
| Engine Electrical System Options and Accessories |
| Batteries |  |  |  |  |
| Battery Rack |  |  |  |  |
| Battery Cables |  |  |  |  |
| Battery Charger (Automatic) |  |  |  |  |
| Engine Fuel System Options and Accessories |
| Sub-Base Fuel Tank |  |  |  |  |
| Flexible Fuel Lines |  |  |  |  |
| Miscellaneous Options and Accessories |
| Weather-Protective Enclosure |  |  |  |  |
| Coolant Heater |  |  |  |  |
NOTES: For ratings and voltages not listed above consult Tele-Lite.
Standby ratings do not have an overload capability but can be used for the duration of the utility failure per ISO-3046, DIN6271 and BS5514.
Base load (continuous) ratings are continuous per DIN 6271, BS 5514 and ISO-8528 with no sustained overload capacity.
Consult factory for base load ratings.
Altitude derate is 4% for each 1000 feet over 5000.
Temperature derate is 1% for 10°F over 100°F ambient. |
|

|
|
 |